Comparison of CAIPIRINHA-accelerated 3D fat-saturated-SPACE MRI with 2D MRI sequences for the assessment of shoulder pathology

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Dept Radiol, Tongji Hosp, Tongji Med Coll, Wuhan, Hubei, Peoples R China [2]Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
出处:
ISSN:

关键词: Magnetic resonance imaging Shoulder Imaging three-dimensional Acceleration

摘要:
Objectives To compare the performance of 6-min MRI with a fat-saturated 3D-controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) Sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) TSE protocol with 10-min 2D TSE MRI protocol for assessment of abnormalities of the shoulder. Methods Forty-nine subjects underwent both 3D fat-saturated-CAIPIRINHA SPACE and 2D TSE sequences of the shoulder on a 3.0-T system. Following randomization and anonymization, two musculoskeletal radiologists evaluated the 2D and 3D images independently for image quality and diagnostic capability. Descriptive statistics, inter-observer, and inter-method concordance were investigated. p values < 0.05 were considered significant. Results For image quality assessment, 2D images were similar to 3D CAIPIRINHA SPACE images (p = 0.05). 3D had lower noise standard deviation (SD) and higher fluid CNR than 2D images (p = 0.00). For diagnostic capability assessment, using 2D TSE as a standard of reference, sensitivity, specificity, and accuracy of 3D SPACE were, respectively, 94.81%, 94.12%, and 94.39% for tendon abnormalities; 97.06%, 80.00%, and 91.84% for acromioclavicular joint abnormalities; 88.89%, 100.00%, and 93.89% for adjacent bone alterations; and 97.30%, 100%, and 97.96% for joint fluid/effusion assessment. The inter-method concordance was moderate to almost perfect. The inter-observer-concordance of the shoulder assessment was also moderate to almost perfect, with SSP lesions demonstrating the greatest concordance. Conclusions The performance of 6-min 3D fat-saturated-CAIPIRINHA SPACE MRI for shoulder MRI is similar to that of 10-min 2D TSE MRI. 3D fat-saturated-CAIPIRINHA SPACE MRI can be utilized to reduce scan time without degradation in image quality.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2020]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Dept Radiol, Tongji Hosp, Tongji Med Coll, Wuhan, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)