Diagnostic performance of a new two-dimensional shear wave elastography expression using siemens ultrasound system combined with ACR TI-RADS for classification of benign and malignant thyroid nodules: A prospective multi-center study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230601, PR China. [2]The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, PR China. [3]Department of Medical Ultrasound, The Fourth Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230012, PR China. [4]Department of Medical Ultrasound, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430030, PR China.
出处:

关键词: Thyroid nodules Ultrasound Two-dimensional shear wave elastography ACR TI-RADS Pathology

摘要:
The present study aimed to evaluate the efficacy of a new two-dimensional shear wave elastography (2D-SWE) method using a Siemens ultrasound system and its combination with the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) for the differential diagnosis of benign and malignant thyroid nodules.Conventional ultrasound images and 2D-SWE (E-whole-mean and E-stiffest-mean) were prospectively analyzed in 593 thyroid nodules from 543 patients. Nodules were divided into diameter (D) ≤10 mm and D > 10 mm groups and graded using ACR TI-RADS. The receiver operating characteristic curve was plotted using pathological findings as the gold standard. Diagnostic performance was compared among 2D-SWE, ACR TI-RADS, and their combination.The area under the curve (AUC) for E-whole-mean was higher than that for E-stiffest-mean (0.858 vs. 0.790, P < 0.001), which indicated that it was the better 2D-SWE parameter for differentiating malignant nodules from benign nodules with an optimal cut-off point of 11.36 kPa. In the all-sizes group, the AUC for E-whole-mean was higher than that for ACR TI-RADS (0.858 vs. 0.808, P < 0.001). The combination of E-whole-mean and ACR TI-RADS resulted in a higher AUC (0.929 vs. 0.858 vs. 0.808, P < 0.001), sensitivity (87.0% vs. 80.3% vs. 85.2%), specificity (85.1% vs. 74.0% vs. 73.6%), accuracy (86.3% vs. 78.1% vs. 81.1%), positive predictive value (91.5% vs. 85.1% vs. 85.6%), and negative predictive value (78.0% vs. 67.0% vs. 72.9%) compared to E-whole-mean or ACR TI-RADS alone. The AUC for the combination of 2D-SWE and ACR TI-RADS was superior to that for E-whole-mean or ACR TI-RADS alone in both D ≤ 10 mm and D > 10 mm groups (P < 0.001).As the better 2D-SWE parameter, E-whole-mean had a higher diagnostic power than ACR TI-RADS and enhanced the diagnostic performance of ACR TI-RADS when identifying benign and malignant thyroid nodules. The combination of E-whole-mean and ACR TI-RADS improved the diagnostic performance compared to using ACR TI-RADS alone, providing a new and reliable method for the clinical diagnosis of thyroid nodules.© 2023 Published by Elsevier Ltd.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 综合性期刊
小类 | 4 区 综合性期刊
最新[2025]版:
大类 | 4 区 综合性期刊
小类 | 4 区 综合性期刊
JCR分区:
出版当年[2021]版:
Q2 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230601, PR China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:590 今日访问量:0 总访问量:442 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)