高级检索
当前位置: 首页 > 详情页

Contrast-enhanced ultrasound and shear wave elastography in the diagnosis of ACR TI-RADS 4 and 5 category thyroid nodules coexisting with Hashimoto's thyroiditis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Yueyang Cent Hosp, Dept Med Ultrasound, Yueyang, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Med Ultrasound, Wuhan, Peoples R China [3]Kliniken Hirslanden Beau Site Salem & Permanence, Dept Allgemeine Innere Med, Bern, Switzerland
出处:
ISSN:

关键词: shear wave elastography Hashimoto's thyroiditis thyroid nodule American College of Radiology thyroid imaging reporting and data system contrast-enhanced ultrasound

摘要:
ObjectiveThis study aims to evaluate the value of contrast-enhanced ultrasound (CEUS), shear wave elastography (SWE), and their combined use in the differentiation of American College of Radiology (ACR) thyroid imaging reporting and data system (TI-RADS) 4 and 5 category thyroid nodules coexisting with Hashimoto's thyroiditis (HT). Materials and methodsA total of 133 pathologically confirmed ACR TI-RADS 4 and 5 category nodules coexisting with HT in 113 patients were included; CEUS and SWE were performed for all nodules. The sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), accuracy, and the area under the receiver operating characteristic curve (AUC) of the SWE, CEUS, and the combined use of both for the differentiation of benign and malignant nodules were compared, respectively. ResultsUsing CEUS alone, the sensitivity, specificity, PPV, NPV, and accuracy were 89.2%, 66.0%, 81.3%, 78.6%, and 80.5%, respectively. Using SWE alone, Emax was superior to Emin, Emean, and Eratio for the differentiation of benign and malignant nodules with the best cutoff Emax >46.8 kPa, which had sensitivity of 65.1%, specificity of 90.0%, PPV of 91.5%, NPV of 60.8%, and accuracy of 74.4%, respectively. Compared with the diagnostic performance of qualitative CEUS or/and quantitative SWE, the combination of CEUS and SWE had the best sensitivity, accuracy, and AUC; the sensitivity, specificity, PPV, NPV, accuracy, and AUC were 94.0%, 66.0%, 82.1%, 86.8%, 83.5%, and 0.80 (95% confidence interval: 0.713, 0.886), respectively. ConclusionIn conclusion, CEUS and SWE were useful for the differentiation of benign and malignant ACR TI-RADS 4 and 5 category thyroid nodules coexisting with HT. The combination of CEUS and SWE could improve the sensitivity and accuracy compared with using CEUS or SWE alone. It could be a non-invasive, reliable, and useful method to differentiate benign from malignant ACR TI-RADS 4 and 5 category thyroid nodules coexisting with HT.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 3 区 肿瘤学
最新[2025]版:
大类 | 3 区 医学
小类 | 4 区 肿瘤学
JCR分区:
出版当年[2021]版:
Q2 ONCOLOGY
最新[2023]版:
Q2 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Yueyang Cent Hosp, Dept Med Ultrasound, Yueyang, Peoples R China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)