高级检索
当前位置: 首页 > 详情页

The value of quantitative and a new qualitative color pattern shear wave elastography for the differentiation of ACR TI-RADS 4 or 5 category thyroid nodules measuring ≤10 mm

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of medical ultrasound, Yueyang Central Hospital, Yueyang, China. [2]Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. [3]Department Allgemeine Innere Medizin, Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland.
出处:
ISSN:

关键词: thyroid nodule ultrasonography shear wave elastography ACR TI-RADS color pattern

摘要:
This study aims to evaluate the diagnostic performance of quantitative shear wave elastography (SWE) and a new qualitative color pattern SWE for the differentiation of benign and malignant American College of Radiology Thyroid Imaging, Reporting, and Data System (ACR TI-RADS) 4 or 5 category thyroid nodules measuring ≤10 mm.From May 2020 to July 2022, a total of 237 patients with 270 thyroid nodules were enrolled, and conventional ultrasound and SWE examinations were performed for each patient. Each ACR TI-RADS 4 or 5 category thyroid nodule measuring ≤10 mm was evaluated by quantitative SWE and a new qualitative color pattern SWE. The diagnostic performance of quantitative SWE parameters, the new qualitative color pattern SWE, and the combination of SWE with ACR TI-RADS, respectively, for the differentiation of benign and malignant ACR TI-RADS 4 or 5 category thyroid nodules measuring ≤10 mm was evaluated and compared.Among 270 thyroid nodules in 237 patients, 72 (26.67%) thyroid nodules were benign and 198 (73.33%) thyroid nodules were malignant. The qualitative color pattern SWE showed better diagnostic performance than the quantitative SWE parameters. When combining the qualitative color pattern SWE with ACR TI-RADS scores, with the optimal cutoff value of the total points ≥8, the thyroid nodules were considered malignant. The sensitivity, specificity, accuracy, and AUC were 89.90%, 56.94%, 81.11%, and 0.820 (95% CI: 0.768-0.864), respectively. Compared with using qualitative color pattern SWE alone, the combination of qualitative color pattern SWE and ACR TI-RADS had better diagnostic performance, which was significantly different (p < 0.05).The combination of qualitative SWE color patterns and ACR TI-RADS had high sensitivity and accuracy, which might be a convenient and useful method to differentiate benign and malignant ACR TI-RADS 4 or 5 category thyroid nodules measuring ≤10 mm. It would be helpful for the management of thyroid nodules and improving prognosis.Copyright © 2024 Yi, Yang, Cui, Dietrich and Wang.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 2 区 内分泌学与代谢
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 内分泌学与代谢
JCR分区:
出版当年[2022]版:
Q1 ENDOCRINOLOGY & METABOLISM
最新[2023]版:
Q2 ENDOCRINOLOGY & METABOLISM

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者单位: [1]Department of medical ultrasound, Yueyang Central Hospital, Yueyang, China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:589 今日访问量:0 总访问量:441 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)