高级检索
当前位置: 首页 > 详情页

Ultrasound super-resolution imaging for the differential diagnosis of thyroid nodules: A pilot study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Wuhan Univ Sci & Technol, China Resources & Wisco Gen Hosp, Dept Med Ultrasound, Wuhan, Peoples R China [2]Wuhan Univ Sci & technol, Hubei Prov Key Lab Occupat Hazard Identificat & Co, Wuhan, Peoples R China [3]Queens Univ Belfast, Dept Chem & Chem Engn, Belfast, North Ireland [4]Hubei Univ Technol, Dept Elect & Elect Engn, Wuhan, Peoples R China [5]London South Bank Univ, Dept Elect & Elect Engn, London, England [6]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Med Ultrasound, Wuhan, Peoples R China
出处:
ISSN:

关键词: thyroid nodule super-resolution ultrasound imaging microbubble contrast-enhanced ultrasound

摘要:
ObjectiveUltrasound imaging provides a fast and safe examination of thyroid nodules. Recently, the introduction of super-resolution imaging technique shows the capability of breaking the Ultrasound diffraction limit in imaging the micro-vessels. The aim of this study was to evaluate its feasibility and value for the differentiation of thyroid nodules. MethodsIn this study, B-mode, contrast-enhanced ultrasound, and color Doppler flow imaging examinations were performed on thyroid nodules in 24 patients. Super-resolution imaging was performed to visualize the microvasculature with finer details. Microvascular flow rate (MFR) and micro-vessel density (MVD) within thyroid nodules were computed. The MFR and MVD were used to differentiate the benign and malignant thyroid nodules with pathological results as a gold standard. ResultsSuper-resolution imaging (SRI) technique can be successfully applied on human thyroid nodules to visualize the microvasculature with finer details and obtain the useful clinical information MVD and MFR to help differential diagnosis. The results suggested that the mean value of the MFR within benign thyroid nodule was 16.76 +/- 6.82 mm/s whereas that within malignant thyroid was 9.86 +/- 4.54 mm/s. The mean value of the MVD within benign thyroid was 0.78 while the value for malignant thyroid region was 0.59. MFR and MVD within the benign thyroid nodules were significantly higher than those within the malignant thyroid nodules respectively (p < 0.01). ConclusionsThis study demonstrates the feasibility of ultrasound super-resolution imaging to show micro-vessels of human thyroid nodules via a clinical ultrasound platform. The important imaging markers, such as MVD and MFR, can be derived from SRI to provide more useful clinical information. It has the potential to be a new tool for aiding differential diagnosis of thyroid nodules.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 肿瘤学
最新[2025]版:
大类 | 3 区 医学
小类 | 4 区 肿瘤学
JCR分区:
出版当年[2020]版:
Q2 ONCOLOGY
最新[2023]版:
Q2 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Wuhan Univ Sci & Technol, China Resources & Wisco Gen Hosp, Dept Med Ultrasound, Wuhan, Peoples R China [2]Wuhan Univ Sci & technol, Hubei Prov Key Lab Occupat Hazard Identificat & Co, Wuhan, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)