高级检索
当前位置: 首页 > 详情页

Do Radiographic Results of Transforaminal Lumbar Interbody Fusion Vary with Cage Position in Patients with Degenerative Lumbar Diseases?

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Orthoped,1095 Jiefang Ave,Wuhan 430030,Hubei,Peoples R China [2]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Radiol,Wuhan,Peoples R China
出处:
ISSN:

关键词: Cage position Disc height Foraminal height Segmental lumbar lordosis Transforaminal lumbar interbody fusion

摘要:
Objective To investigate whether the radiographic results are affected by cage position in single-level transforaminal lumbar interbody fusion (TLIF). Method Between January 2016 and June 2018, 130 patients (62 males and 68 females, average age: 55.28 +/- 10.11 years) who underwent single-level TLIF were analyzed retrospectively. Standing lateral radiographs of the lumbar spine were collected and evaluated preoperatively, postoperatively, and at the time of last follow-up. Cage position in the fused segment was recorded using a central point ratio (CPR), which indicated the cage position. CPR is calculated by dividing the distance between the cage center point and the posterior extent of the superior endplate of the inferior vertebra by the length of the superior endplate of the inferior vertebra. Based on cage positions, the patients were divided into three groups: Anterior Group (n = 38); Middle Group (n = 68); and Posterior Group (n = 24). Segmental lumbar lordosis (SLL), foraminal height (FH), posterior disc height (PDH), and anterior disc height (ADH) were evaluated. A subanalysis was also performed on cage height within each group. Results The average follow-up time of the patients was 35.20 +/- 4.43 months. The mean values of CPR in Anterior Group, Middle Group, and Posterior Group were 0.64, 0.51, and 0.37, respectively. The FH, PDH, and ADH were significantly increased after TLIF in all groups (P < 0.05). There were significant differences in increase of SLL in Anterior Group (4.4 degrees) and Middle Group (3.0 degrees), but not in Posterior Group (0.3 degrees). Furthermore, in the comparison of the three groups, the increase of SLL, FH, and PDH was statistically different (P < 0.05), while not for ADH (P > 0.05). The significant correlations in surgery were: CPR and Delta SLL (r = 0.584, P < 0.001), CPR and Delta FH (r = -0.411, P < 0.001), and CPR and Delta PDH (r = -0.457, P < 0.001). However, ADH had a positive correlation with cage height when the cage was located in anterior and middle of the endplate. Moreover, cage height had a positive correlation with SLL when the cage was located anteriorly and had a negative correlation with SLL when the cage was located posteriorly. FH and PDH both had a positive correlation with cage height in any cage position. Conclusion The cage located in different positions has different effects on radiographic results in single-level TLIF. A thicker cage located anteriorly will gain maximum SLL and avoid the reduction of FH and PDH.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 2 区 医学
小类 | 2 区 骨科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 骨科
JCR分区:
出版当年[2020]版:
Q3 ORTHOPEDICS
最新[2023]版:
Q2 ORTHOPEDICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Orthoped,1095 Jiefang Ave,Wuhan 430030,Hubei,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:0 总访问量:413 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题