高级检索
当前位置: 首页 > 详情页

Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Orthopaed,Wuhan 430030,Hubei,Peoples R China [2]San Xia Univ, Dept Orthopaed, People Hosp Yichang 1, Yichang 443000, Hubei, Peoples R China [3]Capital Med Univ, Beijing Chaoyang Hosp, Dept Orthopaed, Beijing 100020, Peoples R China
出处:
ISSN:

关键词: minimally invasive spine surgery computer-assisted navigation transforaminal lumbar interbody fusion electromyographic monitoring

摘要:
Background Minimally invasive techniques are gaining wide-spread application in lumbar fusion surgery, because they may have advantage over conventional open surgery in approach-related morbidity. This research was aimed to evaluate the safety and accuracy of the techniques of minimally invasive transforaminal lumbar interbody fusion by using a computer-assisted spinal navigation system combined with electromyography monitoring. Methods Sixteen patients underwent minimally invasive transforaminal lumbar interbody fusion. A computer-assisted spinal navigation system and electromyography were used for guiding pedicle screw placement. The operative duration, blood loss, complications, and fluoroscopic time were recorded. Clinical outcome was assessed by Visual Analog Scale and Oswestry Disability Index. Radiographic images were obtained to evaluate the accuracy of pedicle screw placement and fusion rates. Results The Visual Analog Scale and Oswestry Disability Index scores were vastly improved postoperatively. A total of 64 pedicle screws were implanted and three were regarded as misplacement by post-operative CT scan. Three screw trajectories were adjusted according to intra-operative stimulus-evoked electromyography monitoring. The average fluoroscopy time in each patient was 31.8 seconds, which equals to 7.9 seconds per pedicle screw. No patients had instrument related neurological complications, infection, implant failure or revision. Successful fusion was found in all patients. Conclusions The combination of navigation system and real-time electromyography monitoring can make the minimally invasive operation more safe and accurate while decreasing radiation exposure time of the medical staff and patient and minimizing the chance and the degree of the pedicle screw misplacement. Chin Med J 2012;125(22):3947-3951

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
JCR分区:
出版当年[2010]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Orthopaed,Wuhan 430030,Hubei,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:0 总访问量:413 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)