高级检索
当前位置: 首页 > 详情页

Assessment of renal function using magnetic resonance quantitative histogram analysis based on spatial labeling with multiple inversion pulses

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China [2]Department of Radiology and Radiological Science, The Johns Hopkins Hospital, Baltimore, MD, USA
出处:
ISSN:

关键词: Histogram analysis magnetic resonance imaging renal function

摘要:
Background: The incidence of chronic kidney disease (CKD) is high, and is easy to develop into endstage renal disease (ESRD), which requires kidney dialysis or kidney transplantation. Therefore, we want to explore the clinical value of magnetic resonance quantitative histogram analysis based on spatial labeling with multiple inversion pulses (SLEEK) in assessing renal function in the early stage. Methods: One hundred and twenty- nine patients underwent abdominal MRI examination, including a coronal SLEEK sequence. The patients were divided into the control group [CG, 47 cases, estimated glomerular filtration rate (eGFR) >90], the mild renal function impairment (mRI) group (48 cases, eGFR =60-90), and the moderate to severe renal function impairment (m-sRI) group (34 cases, eGFR <60). Two experienced radiologists delineated cortex and medulla regions of interest ( ROIs) on SLEEK images to obtain cortex and medulla quantitative histogram parameters [Mean, Median, Percentiles (5th, 10th, 25th, 75th, and 90th), Skewness, Kurtosis, and Entropy] using FireVoxel. These histogram parameters were compared by proper statistical methods such as one-way analysis of variance, the.2 test, and receiver operating characteristic (ROC) curve analysis. Results: Four histogram parameters (Inhomogeneity(cortex), Skewness(cortex), Kurtosis(medull)a, and Entropy(medulla)) differed significantly between the CG and the mRI group. One medulla (Entropy(medul)la) and nine cortex (Mean(cortex), Median(cortex), Kurtosiscortex, Entropycortex, and 5th, 10th, 25th, 75th, and 90th Percentile(cortex)) histogram parameters were significantly different between the m-RI and m-sRI groups. The most relevant parameter to eGFR was Inhomogenity(cortex) (r=-0.450, P<0.001). Inhomogeneity(cortex) had the largest area under the curve (AUC) for differentiating the mRI group from the CG (AUC =0.718, 95% CI, 0.616-0.806), while 25th Percentile(cortex) generated the largest AUC (AUC =0.786, 95% CI, 0.681-0.869) for differentiating the mRI and m-sRI groups. Conclusions: Quantitative histogram parameters based on a SLEEK sequence can be used to supplement renal dysfunction assessment. Cortex histogram parameters are more valuable for evaluating renal function than medulla histogram parameters.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版
大类 | 3 区 医学
小类 | 3 区 医学:研究与实验 3 区 肿瘤学
最新[2025]版:
JCR分区:
出版当年[2019]版:
Q2 ONCOLOGY Q2 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
通讯作者:
通讯机构: [1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China [*1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan 430030, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:428 今日访问量:1 总访问量:411 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)