高级检索
当前位置: 首页 > 详情页

Reference values of respiratory impedance with impulse oscillometry in healthy Chinese adults

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Guangzhou Med Univ, Guangzhou Inst Resp Hlth, State Key Lab Resp Dis, Affiliated Hosp 1,Natl Clin Res Ctr Resp Dis, Guangzhou, Peoples R China [2]Sichuan Univ, West China Hosp, Dept Resp & Crit Care, Chengdu, Peoples R China [3]Fujian Med Univ, Affiliated Hosp 1, Dept Resp Med, Fuzhou, Peoples R China [4]Shanxi Med Univ, Hosp 3, Shanxi Bethune Hosp,Shanxi Acad Med Sci, Dept Resp & Crit Care Med,Tongji Shanxi Hosp, Taiyuan, Peoples R China [5]Tongji Univ, Sch Med, Shanghai Pulm Hosp, Dept Pulm Funct Test, Shanghai, Peoples R China [6]Capital Med Univ, Dept Resp & Crit Care Med, Beijing Inst Resp Med, Beijing, Peoples R China [7]Capital Med Univ, Beijing Chao Yang Hosp, Beijing, Peoples R China [8]Huazhong Univ Sci & Technol, Union Hosp Tongji Med Coll, Dept Resp Med, Wuhan, Peoples R China [9]Cent South Univ, Xiangya Hosp, Branch Natl Clin Res Ctr Resp Dis, Natl Key Clin Specialty,Dept Resp Med, Changsha, Peoples R China [10]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Resp & Crit Care Med, Wuhan, Peoples R China
出处:
ISSN:

关键词: Reference values respiratory impedance impulse oscillometry (IO) forced oscillation technique (FOT) adult

摘要:
Background: Impulse oscillometry (IO) is a non-invasive pulmonary function test for measuring respiratory impedance. Available reference equations of IO indices for adults are limited. The aim of this study was to develop reference equations of IO indices for Chinese adults. Methods: In a multicentral, cross-sessional study of IO in Chinese adults, IO data from healthy subjects were collected from 19 general hospitals across China between 2016 and 2018. Oscillometry measurements were conducted in accordance with recommendations of the European Respiratory Society (ERS). Multiple linear regression was performed to develop sex-specific reference equations of IO indices. Results: IO measurements were performed in 1,318 subjects, of which 567 subjects were defined as healthy individuals with acceptable IO data and were included in the final analysis. Reference equations and limits of normal [lower limit of normal (LLN)/upper limit of normal (ULN)] of IO indices were developed separately for males and females. Height but not age was shown to be the most influential contributor to IO indices. The reference equations currently used in lung function laboratories predicted higher R5 and X5. Normal ranges of R5 and X5 recommended by the equipment manufacturer were clearly different from the ULN/ LLN derived from the reference equations. Conclusions: Reference equations of IO indices for Chinese adults from a wide region were provided in this study. It is necessary to update new IO reference equations and adopt ULN/LLN as normal ranges of IO indices. Trial Registration: This study was registered at www.clinicaltrials.gov as part of a larger study NCT03467880.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 呼吸系统
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 呼吸系统
JCR分区:
出版当年[2019]版:
Q3 RESPIRATORY SYSTEM
最新[2024]版:
Q3 RESPIRATORY SYSTEM

影响因子: 最新[2024版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Guangzhou Med Univ, Guangzhou Inst Resp Hlth, State Key Lab Resp Dis, Affiliated Hosp 1,Natl Clin Res Ctr Resp Dis, Guangzhou, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:811 今日访问量:0 总访问量:560 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)