资源类型:
期刊
WOS体系:
Review
Pubmed体系:
Journal Article;Review
收录情况:
◇ ESCI
文章类型:
综述,论著
作者:
Zander, David[1]
*
;
Hueske, Sebastian[1]
;
Hoffmann, Beatrice[2]
;
Cui, Xin-Wu[3]
;
Dong, Yi[4]
;
Lim, Adrian[5,6]
;
Jenssen, Christian[7]
;
Loewe, Axel[8]
;
Koch, Jonas B. H.[8]
;
Dietrich, Christoph F.[8]
;
单位:
[1]Ruprecht Karls Univ Heidelberg, Heidelberg Med Sch, Heidelberg, Germany
[2]Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Emergency Med, Boston, MA 02115 USA
[3]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Med Ultrasound, Wuhan, Peoples R China
超声影像科
华中科技大学同济医学院附属同济医院
[4]Fudan Univ, Zhongshan Hosp, Ultrasound Dept, Shanghai, Peoples R China
[5]Imperial Coll Healthcare NHS Trust, Imaging Dept, London, England
[6]Imperial Coll Healthcare NHS Trust, Imaging Dept, London, North Ireland
[7]Med Univ Brandenburg, Strausberg & Brandenburg Insitute Clin Ultrasound, Krankenhaus Markisch Oderland GmbH, Klin Innere Med, Neuruppin, Germany
[8]Hirslanden Clin Beau Site Salem & Permanence, Dept Gen Internal Med, Schanzlihalde 11, CH-3013 Bern, Switzerland
ISSN:
2509-596X
关键词:
ultrasound
Methods & techniques
B-mode
resolution
image quality
image optimization
摘要:
Ultrasound is a ubiquitous and indispensable diagnostic and therapeutic tool in medicine. Due to modern equipment and automatic image optimization, the introduction of ultrasound imaging currently requires only little technical and physical knowledge. However, in-depth knowledge of the device functions and underlying mechanisms is essential for optimal image adjustment and documentation. From a medical as well as an aesthetic point of view, the goal should always be to achieve the best possible image quality. The first part of this article provides an overview of the handling of ultrasound systems, fundamental adjustments, and their optimization in B-mode ultrasound.
被引次数:
44
WOS:
WOS:000564249000001
PubmedID:
32885137
中科院(CAS)分区:
最新[2025]版:
大类
|
4 区
医学
小类
|
4 区
核医学
JCR分区:
最新[2023]版:
Q3
RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
影响因子:
1.3
最新[2023版]
2.7
最新五年平均
0
出版当年[2018版]
0
出版当年五年平均
0
出版前一年[2017版]
第一作者:
Zander, David
第一作者单位:
[1]Ruprecht Karls Univ Heidelberg, Heidelberg Med Sch, Heidelberg, Germany
通讯作者:
Dietrich, Christoph F.
推荐引用方式(GB/T 7714):
Zander David,Hueske Sebastian,Hoffmann Beatrice,et al.Ultrasound Image Optimization ("Knobology"): B-Mode[J].ULTRASOUND INTERNATIONAL OPEN.2020,06(01):E14-E24.doi:10.1055/a-1223-1134.
APA:
Zander, David,Hueske, Sebastian,Hoffmann, Beatrice,Cui, Xin-Wu,Dong, Yi...&Dietrich, Christoph F..(2020).Ultrasound Image Optimization ("Knobology"): B-Mode.ULTRASOUND INTERNATIONAL OPEN,06,(01)
MLA:
Zander, David,et al."Ultrasound Image Optimization ("Knobology"): B-Mode".ULTRASOUND INTERNATIONAL OPEN 06..01(2020):E14-E24