The safety and efficacy of zero-fluoroscopy ablation versus conventional ablation in patients with supraventricular tachycardia

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Internal Med,Div Cardiol,1095 Jiefang Ave,Wuhan 430030,Peoples R China [2]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Hlth Management Ctr,Wuhan,Peoples R China
出处:
ISSN:

关键词: ablation radiation supraventricular tachycardia 3-dimensional zero fluoroscopy

摘要:
BACKGROUND A zero-fluoroscopy approach guided by a 3-dimensional navigation system is an alternative to the traditional conventional fluoroscopy-navigation approach for ablation of tachycardia. AIMS To compare the safety and efficacy of zero-fluoroscopy ablation of supraventricular tachycardia (SVT) guided by the CARTO mapping system (CZF) alone, the EnSite zero-fluoroscopy mapping system (EZF) alone, or the conventional fluoroscopy (CF) ablation method. METHODS From July 2015 to March 2017, patients admitted for SVT ablation were prospectively and consecutively enrolled in the CF, EZF, and CZF groups in a 1:1:1 ratio. The procedures for the CF group were performed using the traditional fluoroscopy method or the 3-dimensional mapping method. All data were prospectively recorded by independent researchers. Procedure and fluoroscopic time as well as rate of success, recurrence, and complications in the 3 groups were analyzed. RESULTS One patient from the CZF group was moved to the CF group due to a severe venous malformation during catheter insertion. A total of 100 patients (100%) in the CF group, 100 patients (100%) in the EZF group (100%), and 99 patients (99%) in the CZF group successfully completed the electrophysiology study. There were no severe complications in any of the groups. The mean (SD) procedure time was 61.8 (36.2), 66.5 (24.2), and 65.4 (27.5) minutes in the CF, EZF, and CZF group, respectively. The median (interquartile range) fluoroscopy time of the CF group was 3.6 (2.1-8.8) minutes. CONCLUSIONS The zero-fluoroscopy approach guided by the CARTO system is not inferior to the zero-fluoroscopy approach guided by the EnSite system or a conventional fluoroscopic approach in terms of the efficiency and safety for ablation of SVT.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 心脏和心血管系统
JCR分区:
出版当年[2018]版:
Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q1 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Internal Med,Div Cardiol,1095 Jiefang Ave,Wuhan 430030,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)