Background: Three-dimensional electroanatomic mapping systems have demonstrated a significant reduction in radiation exposure during radiofrequency catheter ablation procedures. We aimed to investigate the safety, feasibility and efficacy of a completely zero-fluoroscopy approach for catheter ablation of supraventricular tachycardia using the Ensite NavX navigation system compared with a conventional fluoroscopy approach. Methods: A multicenter prospective non-randomized registry study was performed in seven centers from January 2013 to February 2018. Consecutive patients referred for catheter ablation of supraventricular tachycardia were assigned either to a completely zero-fluoroscopic approach (ZF) or conventional fluoroscopy approach (CF) according to the operator's preference. Patients with atrial tachycardia were excluded. Results: Totally, 1020 patients were enrolled in ZF group; 2040 patients ablated by CF approach were selected for controls. There was no significant difference between the zero-fluoroscopy group and conventional fluoroscopy group as to procedure time (60.3 +/- 20.3 vs. 59.7 +/- 22.6 min, P=0.90), immediate success rate of procedure (98.8% vs. 99.2%, P=0.22), arrhythmia recurrence (0.4% vs. 0.5%, P=0.85), total success rate of procedure (98.4% vs. 98.8%, P=0.39) or complications (1.1% vs. 1.5%, P=0.41). Compared with the conventional fluoroscopy approach, the zero-fluoroscopy approach provided similar outcomes without compromising the safety or efficacy of the procedure. Conclusion: The completely zero-fluoroscopy approach demonstrated safety and efficacy comparable to a conventional fluoroscopy approach for catheter ablation of supraventricular tachycardia, and mitigated radiation exposure to both patients and operators.
基金:
Science and Technology Department of Hubei Province [2015CFA077]; National Natural Science Foundation of China [81400369, 81570308]
第一作者单位:[1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Div Cardiol,Dept Internal Med, Wuhan 430030, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
Chen Guangzhi,Wang Yan,Proietti Riccardo,et al.Zero-fluoroscopy approach for ablation of supraventricular tachycardia using the Ensite NavX system: a multicenter experience[J].BMC CARDIOVASCULAR DISORDERS.2020,20(1):doi:10.1186/s12872-020-01344-0.
APA:
Chen, Guangzhi,Wang, Yan,Proietti, Riccardo,Wang, Xunzhang,Ouyang, Feifan...&Wang, Dao Wen.(2020).Zero-fluoroscopy approach for ablation of supraventricular tachycardia using the Ensite NavX system: a multicenter experience.BMC CARDIOVASCULAR DISORDERS,20,(1)
MLA:
Chen, Guangzhi,et al."Zero-fluoroscopy approach for ablation of supraventricular tachycardia using the Ensite NavX system: a multicenter experience".BMC CARDIOVASCULAR DISORDERS 20..1(2020)