高级检索
当前位置: 首页 > 详情页

Time-resolved MR angiography of renal artery stenosis in a swine model at 3 Tesla using gadobutrol with digital subtraction angiography correlation

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Radiol, Wuhan 430074, Hubei, Peoples R China [2]Texas A&M Univ, Scott & White Clin & Hosp, Hlth Sci Ctr, Dept Radiol, Temple, TX USA [3]UTMB, Dept Radiol, Galveston, TX USA [4]Siemens Healthcare Erlangen, Bavaria, Germany [5]USA, Siemens Med Solut, Dallas, TX USA [6]Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Mannheim, Baden Wurttembe, Germany [7]Texas A&M Univ, Inst Preclin Studies TIPS, College Stn, TX USA [8]UTMB, Bioinformat Program, Galveston, TX USA
出处:
ISSN:

关键词: MRA gadobutrol time-resolved MRA

摘要:
Purpose: To establish the minimum dose required for detection of renal artery stenosis using high temporal resolution, contrast enhanced MR angiography (MRA) in a porcine model. Materials and Methods: Surgically created renal artery stenoses were imaged with 3 Tesla MR and digital subtraction angiography (DSA) in 12 swine in this IACUC approved protocol. Gadobutrol was injected intravenously at doses of 0.5, 1, 2, and 4 mL for time-resolved MRA (1.5 x 1.5 mm2 spatial resolution). Region of interest analysis was performed together with stenosis assessment and qualitative evaluation by two blinded readers. Results: Mean signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were statistically significantly less with the 0.5-mL protocol (P < 0.001). There were no statistically significant differences among the other evaluated doses. Both readers found 10/12 cases with the 0.5-mL protocol to be of inadequate diagnostic quality (? = 1.0). All other scans were found to be adequate for diagnosis. Accuracies in distinguishing between mild/insignificant (<50%) and higher grade stenoses (>50%) were comparable among the higher-dose protocols (sensitivities 7393%, specificities 62100%). Conclusion: Renal artery stenosis can be assessed with very low doses ( 0.025 mmol/kg bodyweight) of a high concentration, high relaxivity gadolinium chelate formulation in a swine model, results which are promising with respect to limiting exposure to gadolinium based contrast agents. J. Magn. Reson. Imaging 2012;36:704713. (C) 2012 Wiley Periodicals, Inc.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2010]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者单位: [2]Texas A&M Univ, Scott & White Clin & Hosp, Hlth Sci Ctr, Dept Radiol, Temple, TX USA
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)