高级检索
当前位置: 首页 > 详情页

The effect of non-contrast enhanced MRA on patients with renal insufficiency and foot pain

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology, Tongji Hospital of Tongji Medical College of Huazhong University of Science and Technology, Wuhan, Hubei, China. [2]Internal Medicine of Nephropathy, Hubei No.3 People's Hospital of Jianghan University, Wuhan, Hubei, China. [3]Department of Radiology, Hubei No.3 People's Hospital of Jianghan University, Wuhan, Hubei, China.
出处:
ISSN:

关键词: fast spin echo foot MRA non-contrast enhanced stenosis

摘要:
To investigate the feasibility of non-contrast magnetic resonance angiography of arteries and veins (NATIVE) sampling perfection with application optimized contrasts by using different flip angle evolution (SPACE) and quiescent interval single shot (QISS) in assessing foot arteries of patients with renal insufficiency and foot pain. Fifty-three patients (mean age = 44.2 ± 11.4 years, male: female = 27:26) underwent QISS and NATIVE-SPACE. The source images were reconstructed to maximum intensity projection and volume render. The image quality of QISS and NATIVE-SPACE was rated (0-3, poor to excellent), and was compared using Wilcoxon test. True or false positive was determined by comparing the findings of QISS and NATIVE-SPACE. The relative signal intensity of artery was obtained for each case, and was compared between QISS and NATIVE-SPACE using Mann Whitney test. The acquisition time of NATIVE-SPACE was significantly longer than that of QISS (178.4 ± 35.7 seconds vs 45.4 ± 8.9 seconds, P < .001). QISS had significantly lower image quality score versus NATIVE-SPACE (1.4 ± 0.5 vs 2.4 ± 0.6, P = .02). Fifteen percentage (8/53) NATIVE-SPACE cases had poor image quality due to the similarity of peak flow and minimum flow. The relative signal intensity was significantly lower in QISS versus NATIVE-SPACE (9.7 ± 1.3 vs 68.2 ± 12.4, P < .001). NATIVE-SPACE is valuable in evaluating foot arteries of patients with renal insufficiency. QISS can serve as an alternative test to NATIVE-SPACE.Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2021]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q2 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Department of Radiology, Tongji Hospital of Tongji Medical College of Huazhong University of Science and Technology, Wuhan, Hubei, China.
共同第一作者:
通讯作者:
通讯机构: [3]Department of Radiology, Hubei No.3 People's Hospital of Jianghan University, Wuhan, Hubei, China. [*1]Department of Radiology, Hubei No.3 People’s Hospital of Jianghan University, Wuhan 430033, Hubei, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:1 总访问量:413 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)