Contrast Dose, Temporal Footprint, and Spatial Resolution Tradeoffs in Dynamic Contrast-Enhanced MRA Performed in a Porcine Model of a Carotid Aneurysm

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China [2]Univ Texas Med Branch, Dept Radiol, Galveston, TX 77555 USA
出处:
ISSN:

关键词: brain aneurysm time-resolved contrast-enhanced MRA

摘要:
Objective: To evaluate the tradeoffs between temporal and spatial resolution and contrast dosing in dynamic contrast-enhanced magnetic resonance angiography (CE-MRA). Methods: Bilateral carotid artery aneurysms were created in a swine model. Dynamic CE-MRA using 1 mol/L gadobutrol was performed at 3 T, with high temporal (high-temp), middle temporal (mid-temp), and low temporal (low-temp) resolutions. High temporal CE-MRA was performed twice using 1 mL and 2 mL gadobutrol (2 mL/s). Middle temporal and low-temp sequences were performed once with 2 mL gadobutrol (2 mL/s). The signal-to-noise ratio (SNR) was quantitatively assessed. Blinded reads were used to qualitatively evaluate contrast dose and image quality. Results: The mean SNRs of high-temp, mid-temp, and low-temp resolutions were 56.7, 47.5, and 48.1. There was no significant difference between the 3 sequences with 2 mL gadobutrol. The mean SNR of the high-temp resolution with 2 mL was significantly higher than that with 1 mL (56.7 vs 39.9). In qualitative analysis, the 3 temporal sequences with 2 mL gadobutrol showed no significant differences regarding overall image quality and diagnostic value. High temporal resolution with 2 mL consistently showed the superiority of image quality than that with 1 mL. Conclusions: High temporal dynamic CE-MRA with 2mL (0.04 mmol/kg body weight) gadobutrol can produce consistently superior image quality over that with 1 mL (0.02 mmol/kg body weight). For a given contrast dose, the tradeoffs between temporal and spatial resolution will not result in significant differences in image quality in TWIST (time-resolved angiography with interleaved stochastic trajectories).

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2011]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China [*1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, 1095 Jiefang Ave, Wuhan 430030, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:1 总访问量:413 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)