高级检索
当前位置: 首页 > 详情页

The Diagnostic Accuracy of Evoked Potential Monitoring Techniques During Intracranial Aneurysm Surgery for Predicting Postoperative Ischemic Damage: A Systematic Review and Meta-Analysis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Port Moresby Gen Hosp, Dept Surg, Boroko, Natl Capital Di, Papua N Guinea [2]Huazhong Univ Sci & Technol,Tongji Hosp,Dept Neurosurg,Wuhan,Peoples R China
出处:
ISSN:

关键词: Aneurysm surgery Cerebral Evoked potential monitoring Intracranial Neurologic ischemia Neurophysiologic monitoring Sensitivity and specificity

摘要:
OBJECTIVE: To investigate the diagnostic accuracy of various evoked potential monitoring techniques in predicting postoperative neurologic deficit in intracranial aneurysm surgery. METHODS: A literature search of the MEDLINE, Embase, and Cochrane databases was conducted for English language articles published between March 31, 1983 and March 31, 2016. Original studies that reported the use of evoked potential monitoring during intracranial aneurysm surgery in predicting postoperative neurologic damage were selected, and their relevant reference lists were hand searched. Test performance characteristics were summarized using hierarchic summary receiver operating characteristic (ROC) curves and bivariable random-effects models. RESULTS: Thirteen qualifying studies (1597 patients; 1689 aneurysms) from 6 countries were identified. Eight studies investigated the use of the somatosensory evoked potential (SSEP) monitoring technique, 5 investigated transcranial motor evoked potential (TcMEP) and another 5 investigated direct cortical motor evoked potential (DMEP). Bivariable pooled sensitivity and specificity were 48% (95% confidence interval [CI], 30.7-65.0) and 92% (CI, 88%-94.4%), respectively, for SSEP; 73% (CI, 21.0%-96.7%) and 94% (CI, 87.1%-97.5%) for TcMEP; and 97% (CI, 74.43%-99.99%) and 89% (CI, 84.0%-94.5%) for DMEP. ROC curve analysis showed that TcMEP had the highest accuracy (area under ROC curve 0.95; 95% CI, 0.93-0.97), followed by DMEP (0.91, 0.89-0.94) and SSEP (0.88, 0.85-0.91). CONCLUSIONS: TcMEP and DMEP have higher diagnostic accuracy than SSEP in predicting postoperative neurologic deficit. The type of anesthetic agent, the use of neuromuscular blocking drugs, and the choice of diagnostic criteria for significant change in cerebral blood flow during aneurysm surgery affect the diagnostic accuracy of evoked potential techniques in predicting postoperative neurologic deficit.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 外科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
JCR分区:
出版当年[2015]版:
Q1 SURGERY Q2 CLINICAL NEUROLOGY
最新[2023]版:
Q2 SURGERY Q3 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者单位: [1]Port Moresby Gen Hosp, Dept Surg, Boroko, Natl Capital Di, Papua N Guinea
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:1 总访问量:414 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)