Objectives To evaluate the usefulness of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) in diagnosing focal liver lesions (FLLs) by inexperienced radiologists. Methods Images and clinical data from 258 patients at risk for hepatocellular carcinoma who underwent CEUS were collected retrospectively. Two trained inexperienced radiologists and 2 experienced radiologists reviewed all CEUS clips. Each inexperienced radiologist assigned a CEUS LI-RADS category for each observation and labeled it benign or malignant independently. Each experienced radiologist labeled each lesion malignant or benign independently using a conventional diagnostic method. Interobserver agreement of CEUS LI-RADS was analyzed by the kappa test. The overall diagnostic accuracy of the LI-RADS category and conventional diagnosis was described by the sensitivity, specificity, positive predictive value, and negative predictive value. All test results were considered significant at P < .05. Results A kappa value of 0.774 indicated that the CEUS LI-RADS algorithm resulted in substantial consistency between the inexperienced radiologists. For the diagnosis of hepatocellular carcinoma, the sensitivity, specificity, positive predictive value, and negative predictive value were improved significantly in inexperienced radiologists using the CEUS LI-RADS compared to conventional methods. The overall diagnostic accuracy of the experienced radiologists was almost equal to that of CEUS LI-RADS categories assigned by the inexperienced radiologists. Conclusions The CEUS LI-RADS algorithm can not only obtain substantial consistency among inexperienced radiologists but also have excellent diagnostic efficacy in the differentiation of benign from malignant FLLs compared to conventional methods. As a comprehensive algorithm, the CEUS LI-RADS can act as a guide for trainees in learning how to diagnose FLLs.
基金:
Wuhan Tongji Hospital [2017A002]; Wuhan Science and Technology Bureau [2017060201010181]
语种:
外文
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类|4 区医学
小类|4 区声学4 区核医学
最新[2025]版:
大类|3 区医学
小类|3 区声学3 区核医学
JCR分区:
出版当年[2018]版:
Q2ACOUSTICSQ3RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2ACOUSTICSQ2RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
第一作者单位:[1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Med Ultrasound,Sino German Tongji Caritas Res Ctr Ultrasound Med,1095 Jie Fang Ave,Wuhan 430030,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
Wang Jia-Yu,Feng Shao-Yang,Xu Jian-Wei,et al.Usefulness of the Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System in Diagnosing Focal Liver Lesions by Inexperienced Radiologists[J].JOURNAL OF ULTRASOUND IN MEDICINE.2020,39(8):1537-1546.doi:10.1002/jum.15242.
APA:
Wang, Jia-Yu,Feng, Shao-Yang,Xu, Jian-Wei,Li, Jun,Chu, Liang...&Dietrich, Christoph F..(2020).Usefulness of the Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System in Diagnosing Focal Liver Lesions by Inexperienced Radiologists.JOURNAL OF ULTRASOUND IN MEDICINE,39,(8)
MLA:
Wang, Jia-Yu,et al."Usefulness of the Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System in Diagnosing Focal Liver Lesions by Inexperienced Radiologists".JOURNAL OF ULTRASOUND IN MEDICINE 39..8(2020):1537-1546