高级检索
当前位置: 首页 > 详情页

Usefulness of the Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System in Diagnosing Focal Liver Lesions by Inexperienced Radiologists

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Med Ultrasound,Sino German Tongji Caritas Res Ctr Ultrasound Med,1095 Jie Fang Ave,Wuhan 430030,Peoples R China [2]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Hepat Surg Ctr,Wuhan,Peoples R China [3]Sixth Peoples Hosp Zhengzhou, Dept Ultrasound, Zhengzhou, Peoples R China [4]Zhengzhou Univ, Dept Ultrasound, Affiliated Hosp 1, Zhengzhou, Peoples R China [5]Shihezi Univ, Affiliated Hosp 1, Sch Med, Dept Ultrasound, Xinjiang, Peoples R China [6]Hirslanden Clin, Dept Internal Med, Schanzlihalde 11, Bern, Switzerland
出处:
ISSN:

关键词: contrast-enhanced ultrasound diagnosis hepatocellular carcinoma liver Liver Imaging Reporting and Data System

摘要:
Objectives To evaluate the usefulness of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) in diagnosing focal liver lesions (FLLs) by inexperienced radiologists. Methods Images and clinical data from 258 patients at risk for hepatocellular carcinoma who underwent CEUS were collected retrospectively. Two trained inexperienced radiologists and 2 experienced radiologists reviewed all CEUS clips. Each inexperienced radiologist assigned a CEUS LI-RADS category for each observation and labeled it benign or malignant independently. Each experienced radiologist labeled each lesion malignant or benign independently using a conventional diagnostic method. Interobserver agreement of CEUS LI-RADS was analyzed by the kappa test. The overall diagnostic accuracy of the LI-RADS category and conventional diagnosis was described by the sensitivity, specificity, positive predictive value, and negative predictive value. All test results were considered significant at P < .05. Results A kappa value of 0.774 indicated that the CEUS LI-RADS algorithm resulted in substantial consistency between the inexperienced radiologists. For the diagnosis of hepatocellular carcinoma, the sensitivity, specificity, positive predictive value, and negative predictive value were improved significantly in inexperienced radiologists using the CEUS LI-RADS compared to conventional methods. The overall diagnostic accuracy of the experienced radiologists was almost equal to that of CEUS LI-RADS categories assigned by the inexperienced radiologists. Conclusions The CEUS LI-RADS algorithm can not only obtain substantial consistency among inexperienced radiologists but also have excellent diagnostic efficacy in the differentiation of benign from malignant FLLs compared to conventional methods. As a comprehensive algorithm, the CEUS LI-RADS can act as a guide for trainees in learning how to diagnose FLLs.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 声学 4 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 声学 3 区 核医学
JCR分区:
出版当年[2018]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Med Ultrasound,Sino German Tongji Caritas Res Ctr Ultrasound Med,1095 Jie Fang Ave,Wuhan 430030,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)