Diagnostic Performance and Interobserver Consistency of the Prostate Imaging Reporting and Data System Version 2: A Study on Six Prostate Radiologists with Different Experiences from Half a Year to 17 Years

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Hubei, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Lib, Wuhan 430030, Hubei, Peoples R China
出处:
ISSN:

关键词: Benign Prostatic Hyperplasia Diagnosis Magnetic Resonance Imaging Prostate Cancer Prostate Imaging Reporting and Data System Version 2

摘要:
Background: One of the main aims of the updated Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2) is to diminish variation in the interpretation and reporting of prostate imaging, especially among readers with varied experience levels. This study aimed to retrospectively analyze diagnostic consistency and accuracy for prostate disease among six radiologists with different experience levels from a single center and to evaluate the diagnostic performance of PI-RADS v2 scores in the detection of clinically significant prostate cancer (PCa). Methods: From December 2014 to March 2016, 84 PCa patients and 99 benign prostatic shyperplasia patients who underwent 3.0T multiparametric magnetic resonance imaging before biopsy were included in our study. All patients received evaluation according to the PI-RADS v2 scale (1-5 scores) from six blinded readers (with 6 months and 2, 3, 4, 5, or 17 years of experience, respectively, the last reader was a reviewer/contributor for the PI-RADS v2). The correlation among the readers' scores and the Gleason score (GS) was determined with the Kendall test. Intra-/inter-observer agreement was evaluated using kappa statistics, while receiver operating characteristic curve and area under the curve analyses were performed to evaluate the diagnostic performance of the scores. Results: Based on the PI-RADS v2, the median kappa score and standard error among all possible pairs of readers were 0.506 and 0.043, respectively; the average correlation between the six readers' scores and the GS was positive, exhibiting weak-to-moderate strength (r = 0.391, P = 0.006). The AUC values of the six radiologists were 0.883, 0.924, 0.927, 0.932, 0.929, and 0.947, respectively. Conclusion: The inter-reader agreement for the PI-RADS v2 among the six readers with different experience is weak to moderate. Different experience levels affect the interpretation of MRI images.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
JCR分区:
出版当年[2016]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:428 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)