高级检索
当前位置: 首页 > 详情页

Sufficiency of a Single Negative Thyroglobulin Standard for Judging the Success of Ablation in Low- and Intermediate-risk Differentiated Thyroid Cancer: A Retrospective Study

文献详情

资源类型:
Pubmed体系:
单位: [1]Department of Nuclear Medicine, Department of Nuclear Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, 030032, China. [2]Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. [3]Department of Nuclear Medicine, First Hospital of Shanxi Medical University. Taiyuan 030000, China.
出处:
ISSN:

关键词: Ablation differentiated thyroid carcinoma radioiodine Tc-99m pertechnetate scintigraphy thyroglobulin

摘要:
We investigated how reduced successful ablation criteria may be used to evaluate radioiodine remnant ablation in patients with low- and intermediate-differentiated thyroid carcinoma (DTC).Overall, 254 low- and intermediate-risk patients with DTC were categorized into three groups (positive, weak, positive, and negative) on the basis of a visual study of thyroid imaging performed before postoperative iodine treatment. Semi-quantitative analysis parameters were incorporated into the positive Tc-99m pertechnetate scanning to further examine the clinical use of thyroid imaging. We investigated the value of successful judgment criteria and the influencing factors of radioiodine ablation. At the same time, the predictive value of thyroglobulin (Tg) for radioiodine treatment and the overall clinical efficacy were assessed.A total of 250 (98.43%) patients were identified as having functional thyroid tissue residue on the Tx-whole-body scan, and 137 (53.94%) patients had positive Tc-99m pertechnetate scans using semi-quantitative analysis. The single Tg standard could not substitute the double standard (χ! !=22.042, p<0.001) for patients with residual thyroid weight by a semiquantitative analysis. However, the semi-quantitative analysis revealed no association between 99mTcO4-thyroid scan and ablation treatment using semi-quantitative analysis; only preablation sTg levels were related with success in the multivariate logistic regression analysis, with a cut-off value of 2.88 ng/mL. The pre-ablation stimulated Tg level was also the primary factor of satisfactory response following follow-up with an optimal cut-off of 6.506 ng/mL.Even in low- and intermediate-risk patients with DTC, a single negative Tg standard also requires receiving some restrictions in the evaluation of ablation success and is inadequate. Conventional 99mTcO4 thyroid imaging combined with a quantitative analysis program can improve the clinical practice of single negative Tg standard.Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.net.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 4 区 医学
小类 | 4 区 内分泌学与代谢 4 区 免疫学 4 区 药学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 内分泌学与代谢 4 区 免疫学 4 区 药学
第一作者:
第一作者单位: [1]Department of Nuclear Medicine, Department of Nuclear Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, 030032, China. [2]Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
通讯作者:
通讯机构: [1]Department of Nuclear Medicine, Department of Nuclear Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, 030032, China. [2]Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. [*1]Department of Nuclear Medicine, Department of Nuclear Medicine, Shanxi Bethune Hospital, ShanxiAcademy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, 030032, China [*2]Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:589 今日访问量:0 总访问量:441 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)