The incidence of prostate cancer (PCa) in men globally increases as the standard of living improves. Blood serum biomarker prostate-specific antigen (PSA) detection is the gold standard assay that do not meet the requirements of early detection. Herein, a solution-gated graphene transistor (SGGT) biosensor for the ultrasensitive and rapid quantification detection of the early prostate cancer-relevant biomarker, miRNA-21 is reported. The designed single-stranded DNA (ssDNA) probes immobilized on the Au gate can hybridize effectively with the miRNA-21 molecules targets and induce the Dirac voltage shifts of SGGT transfer curves. The limit of detection (LOD) of the sensor can reach 10(-20) M without amplification and any chemical or biological labeling. The detection linear range is from 10(-20) to 10(-12) M. The sensor can realize real-time detection of the miRNA-21 molecules in less than 5 min and can well distinguish one-mismatched miRNA-21 molecule. The blood serum samples from the patients without RNA extraction and amplification are measured. The results demonstrated that the biosensor can well distinguish the cancer patients from the control group and has higher sensitivity (100%) than PSA detection (58.3%). Contrastingly, it can be found that the PSA level is not directly related to PCa.
基金:
Hubei Provincial Department of Science Technology [2020BIB020]; National Natural Science Foundation of China [51673060]; Opening Project of Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, Jianghan University [JDGD-202205]; Overseas Expertise Introduction Center for Discipline Innovation [D18025]; Natural Science Foundation of Hubei Province [2018CKB910]; Tongji Hospital [2020HGRY016]
第一作者单位:[1]Hubei Univ, Hubei Collaborat Innovat Ctr Adv Organ Chem Mat, Key Lab Green Preparat & Applicat Funct Mat, Minist Educ,Hubei Key Lab Polymer Mat,Sch Mat Sci, Wuhan 430062, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
Deng Minghua,Ren Zhanpeng,Zhang Huibin,et al.Unamplified and Real-Time Label-Free miRNA-21 Detection Using Solution-Gated Graphene Transistors in Prostate Cancer Diagnosis[J].ADVANCED SCIENCE.2023,10(4):doi:10.1002/advs.202205886.
APA:
Deng, Minghua,Ren, Zhanpeng,Zhang, Huibin,Li, Ziqin,Xue, Chenglong...&Li, Jinhua.(2023).Unamplified and Real-Time Label-Free miRNA-21 Detection Using Solution-Gated Graphene Transistors in Prostate Cancer Diagnosis.ADVANCED SCIENCE,10,(4)
MLA:
Deng, Minghua,et al."Unamplified and Real-Time Label-Free miRNA-21 Detection Using Solution-Gated Graphene Transistors in Prostate Cancer Diagnosis".ADVANCED SCIENCE 10..4(2023)