高级检索
当前位置: 首页 > 详情页

Application of Intraoperative Contrast-Enhanced Ultrasound in the Resection of Brain Tumors.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 卓越:梯队期刊

单位: [1]Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. [2]Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
出处:
ISSN:

关键词: intraoperative ultrasound intraoperative contrast-enhanced ultrasound brain tumor hypervascular glioma

摘要:
To investigate the value of routine intraoperative ultrasound (IU) and intraoperative contrast-enhanced ultrasound (ICEUS) in the surgical treatment of brain tumors, and to explore the utilization of ICEUS for the removal of the remnants surrounding the resection cavity.In total, 51 patients who underwent operations from 2012 to 2018 due to different tumors in the brain were included in this study. The clinical data were evaluated retrospectively. IU was performed in all patients, among which 28 patients underwent ICEUS. The effects of IU and ICEUS on tumor resection and recurrence were evaluated. Semiquantitative analysis was performed to compare ICEUS parameters of the brain tumor with those of the surrounding tissue.In total, 36 male and 15 female patients were included in this study. The average age was 43 years (range: 14-68 years). The follow-up period was from 7 to 74 months (mean follow-up 32 months). IU was used in all patients, and no lesion was missed. Among them, 28 patients underwent ICEUS. The rate of total removal of the ICEUS group (23/28, 82%) was significantly higher than that of the IU group (11/23, 48%) (P<0.05). The recurrence rate of ICEUS and IU was 18% (5/23), and 22% (5/28), respectively, and the difference did not reach statistical significance (P>0.05). The semiquantitative analysis showed that the intensity and the transit time of microbubbles reaching the lesions were significantly different from the intensity and the transit time of microbubbles reaching the surrounding tissue (P<0.05) and reflected indirectly the volume and the speed of blood perfusion in the lesions was higher than those in the surrounding tissue.ICEUS is a useful tool in localizing and outlining brain lesions, especially for the resection of the hypervascular lesions in the brain. ICEUS could be more beneficial for identifying the remnants and improving the rate of total removal of these lesions than routine intraoperative ultrasound.© 2022. Huazhong University of Science and Technology.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2020]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:589 今日访问量:0 总访问量:441 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)