NEMA-2008 and In-Vivo Animal and Plant Imaging Performance of the Large FOV Preclinical Digital PET/CT System Discoverist 180

文献详情

资源类型:
WOS体系:

收录情况: ◇ EI ◇ ESCI

单位: [1]Huazhong Univ Sci & Technol, Sch Life Sci & Technol, Wuhan 430074, Peoples R China [2]Ist Neurol Mediterraneo NEUROMED IRCCS, Dept Med Phys & Engn, I-86077 Pozzilli, Italy [3]Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China [4]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Radiol, Wuhan 430074, Peoples R China [5]Huazhong Univ Sci & Technol, Tongji Med Coll, Wuhan 430074, Peoples R China [6]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Oncol, Wuhan 430074, Peoples R China [7]Huazhong Univ Sci & Technol, Dept Software Engn, Wuhan 430074, Peoples R China [8]Turku Univ, Turku PET Ctr, Turku 20500, Finland [9]Turku Univ Hosp, Turku 20500, Finland [10]Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
出处:
ISSN:

关键词: Digital readout multi voltage threshold (MVT) plant positron emission tomography (PET) preclinical neuroscience preclinical PET/computed tomography (CT)

摘要:
The RAYCAN Discoverist 180 (RAYCAN D180) is a novel preclinical positron emission tomography (PET) and computed tomography (CT) integrated system for the imaging of small- and medium-sized animals and plants. We measured a system resolution of (2.56 +/- 0.04) mm (radial), (2.46 +/- 0.05) mm (transverse), and (1.67 +/- 0.03) mm (axial) at the center of the field of view using a filtered backprojection reconstruction algorithm. An OSEM-PSF-3D reconstruction algorithm improves the spatial resolution to (1.34 +/- 0.04) mm (radial), (1.35 +/- 0.05) mm (transverse), and (1.64 +/- 0.04) mm (axial). The peak noise equivalent count rate of the system is (713 +/- 2) kcps, (207 +/- 2) kcps, and (47 +/- 1) kcps reached at approximately 97 MBq for the mouse-, rat- and monkey-like phantoms, respectively. This result is approximately 2x higher and is reached at approximately 3x higher activity in comparison with most of the existing commercial and research scanners. The peak absolute system sensitivity is (4.00 +/- 0.02)% and is competitive with state-of-the-art preclinical PET scanners. We found an image uniformity of (4.86 +/- 0.04)%. Finally, we report the static PET/CT scan of a mouse and of a leaf of Epipremnum aureum, and the time-activity curves of the [F-18]-FDG metabolism in mouse left myocardial ventricle and kidneys obtained with a PET/CT scan in dynamic modality.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2019]版:
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2018]版:
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Sch Life Sci & Technol, Wuhan 430074, Peoples R China
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Sch Life Sci & Technol, Wuhan 430074, Peoples R China [2]Ist Neurol Mediterraneo NEUROMED IRCCS, Dept Med Phys & Engn, I-86077 Pozzilli, Italy [3]Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)