Non-invasive monitoring of blood pressure using the Philips Intellivue MP50 monitor cannot replace invasive blood pressure techniques in surgery patients under general anesthesia

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Urol,Wuhan 430030,Hubei,Peoples R China [2]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Anesthesiol,Wuhan 430030,Hubei,Peoples R China [3]Anhui Inst Geriatr, Maanshan 243000, Anhui, Peoples R China
出处:
ISSN:

关键词: intra-arterial blood pressure oscillometric blood pressure correlation Bland-Altman agreement

摘要:
The Philips Intellivue MP50 monitor provides a method for non-invasive, near-continuous blood pressure (BP) monitoring and is designed to be an alternative to direct intra-arterial BP (IABP) measurement. However, no studies have specifically compared non-invasive and invasive BP measurements using the monitor. The present retrospective study observed 515 patients undergoing surgery with general anesthesia, whose invasive (intra-radial, femoral or dorsalis pedis artery) and non-invasive (oscillometric) BP (NIBP) were monitored simultaneously using the monitor. These data were analyzed using correlations, regressions and Bland-Altman plots. The patients were placed in a supine position during surgery. The correlation data for invasive BP and NIBP measurements were: for intra-radial measurements, r(2)=0.51 (bias and precision, 11.04 +/- 15.22 and 14.76 +/- 11.64 mmHg, respectively) for systolic BP (SBP) and r(2)=0.27 (6.17 +/- 11.95 and 9.77 +/- 9.25 mmHg, respectively) for diastolic BP (DBP); for intra-femoral measurements: r(2)=0.57. (14.79 +/- 14.55 and 17.15 +/- 11.68 mmHg, respectively) for SBP and r(2)=0.45 (4.12 +/- 9.70 and 7.49 +/- 7.40 mmHg, respectively) for DBP; and for intra-dorsalis pedis measurements: r(2)=0.33 (13.00 +/- 16.81 and 17.34 +/- 12.28 mmHg, respectively) for SBP and r(2)=0.30 (0.17 +/- 11.27 and 8.44 +/- 7.46 mmHg, respectively) for DBP. According to this data, the NIBP measured by the Philips Intellivue MP50 monitor showed low positive correlations and poor agreement with the IABP, as calculated by Bland-Altman analysis. Therefore, the use of oscillometric BP measured by the monitor in surgery patients under general anesthesia is not generally recommended.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2011]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Urol,Wuhan 430030,Hubei,Peoples R China
通讯作者:
通讯机构: [2]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Anesthesiol,Wuhan 430030,Hubei,Peoples R China [*1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Anesthesiol,1095 Jiefang Ave,Wuhan 430030,Hubei,Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)