Purpose: The aim of this study was to compare the detection of brain metastases at 3 T using a 32-channel head coil with 2 different 3-dimensional (3D) contrast-enhanced sequences, a T1-weighted fast spin-echo-based (SPACE; sampling perfection with application-optimized contrasts using different flip angle evolutions) sequence and a conventional magnetization-prepared rapid gradient-echo (MP-RAGE) sequence. Materials and Methods: Seventeen patients with 161 brain metastases were examined prospectively using both SPACE and MP-RAGE sequences on a 3-T magnetic resonance system. Eight healthy volunteers were similarly examined for determination of signal-to-noise ratio (SNR) values. Parameters were adjusted to equalize acquisition times between the sequences (3 minutes and 30 seconds). The order in which sequences were performed was randomized. Two blinded board-certified neuroradiologists evaluated the number of detectable metastatic lesions with each sequence relative to a criterion standard reading conducted at the Gamma Knife facility by a neuroradiologist with access to all clinical and imaging data. Results: In the volunteer assessment with SPACE and MP-RAGE, SNR (10.3 +/- 0.8 vs 7.7 +/- 0.7) and contrast-to-noise ratio (0.8 +/- 0.2 vs 0.5 +/- 0.1) were statistically significantly greater with the SPACE sequence (P < 0.05). Overall, lesion detection was markedly improved with the SPACE sequence (99.1% of lesions for reader 1 and 96.3% of lesions for reader 2) compared with the MP-RAGE sequence (73.6% of lesions for reader 1 and 68.5% of lesions for reader 2; P < 0.01). Conclusions: A 3D T1-weighted fast spin echo sequence (SPACE) improves detection of metastatic lesions relative to 3D T1-weighted gradient-echo-based scan (MP-RAGE) imaging when implemented with a 32-channel head coil at identical scan acquisition times (3 minutes and 30 seconds).
第一作者单位:[1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, D-68167 Mannheim, Germany[*1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
通讯作者:
通讯机构:[1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, D-68167 Mannheim, Germany[*1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
推荐引用方式(GB/T 7714):
Reichert Miriam,Morelli John N.,Runge Val M.,et al.Contrast-Enhanced 3-Dimensional SPACE Versus MP-RAGE for the Detection of Brain Metastases Considerations With a 32-Channel Head Coil[J].INVESTIGATIVE RADIOLOGY.2013,48(1):55-60.doi:10.1097/RLI.0b013e318277b1aa.
APA:
Reichert, Miriam,Morelli, John N.,Runge, Val M.,Tao, Ai,von Ritschl, Ruediger...&Attenberger, Ulrike I..(2013).Contrast-Enhanced 3-Dimensional SPACE Versus MP-RAGE for the Detection of Brain Metastases Considerations With a 32-Channel Head Coil.INVESTIGATIVE RADIOLOGY,48,(1)
MLA:
Reichert, Miriam,et al."Contrast-Enhanced 3-Dimensional SPACE Versus MP-RAGE for the Detection of Brain Metastases Considerations With a 32-Channel Head Coil".INVESTIGATIVE RADIOLOGY 48..1(2013):55-60