高级检索
当前位置: 首页 > 详情页

Contrast-Enhanced 3-Dimensional SPACE Versus MP-RAGE for the Detection of Brain Metastases Considerations With a 32-Channel Head Coil

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, D-68167 Mannheim, Germany [2]Texas A&M Hlth Sci Ctr, Dept Radiol, Scott & White Hosp, Temple, TX USA [3]Univ Texas Med Branch, Dept Radiol, Galveston, TX USA [4]Huazhong Univ Sci & Technol, Tonji Med Coll, Dept Radiol, Tongji Hosp, Wuhan 430074, Peoples R China [5]Siemens Med Solut, Malvern, PA USA [6]Methodist Hosp, Gamma Knife Ctr, San Antonio, TX USA
出处:
ISSN:

关键词: brain metastases 3-T MRI 32-channel head coil SPACE MP-RAGE

摘要:
Purpose: The aim of this study was to compare the detection of brain metastases at 3 T using a 32-channel head coil with 2 different 3-dimensional (3D) contrast-enhanced sequences, a T1-weighted fast spin-echo-based (SPACE; sampling perfection with application-optimized contrasts using different flip angle evolutions) sequence and a conventional magnetization-prepared rapid gradient-echo (MP-RAGE) sequence. Materials and Methods: Seventeen patients with 161 brain metastases were examined prospectively using both SPACE and MP-RAGE sequences on a 3-T magnetic resonance system. Eight healthy volunteers were similarly examined for determination of signal-to-noise ratio (SNR) values. Parameters were adjusted to equalize acquisition times between the sequences (3 minutes and 30 seconds). The order in which sequences were performed was randomized. Two blinded board-certified neuroradiologists evaluated the number of detectable metastatic lesions with each sequence relative to a criterion standard reading conducted at the Gamma Knife facility by a neuroradiologist with access to all clinical and imaging data. Results: In the volunteer assessment with SPACE and MP-RAGE, SNR (10.3 +/- 0.8 vs 7.7 +/- 0.7) and contrast-to-noise ratio (0.8 +/- 0.2 vs 0.5 +/- 0.1) were statistically significantly greater with the SPACE sequence (P < 0.05). Overall, lesion detection was markedly improved with the SPACE sequence (99.1% of lesions for reader 1 and 96.3% of lesions for reader 2) compared with the MP-RAGE sequence (73.6% of lesions for reader 1 and 68.5% of lesions for reader 2; P < 0.01). Conclusions: A 3D T1-weighted fast spin echo sequence (SPACE) improves detection of metastatic lesions relative to 3D T1-weighted gradient-echo-based scan (MP-RAGE) imaging when implemented with a 32-channel head coil at identical scan acquisition times (3 minutes and 30 seconds).

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 核医学
JCR分区:
出版当年[2011]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者单位: [1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, D-68167 Mannheim, Germany [*1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
通讯作者:
通讯机构: [1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, D-68167 Mannheim, Germany [*1]Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:590 今日访问量:0 总访问量:442 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)