Reproducibility of high-resolution MRI for the middle cerebral artery plaque at 3 T

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Guangdong Gen Hosp, Guangdong Acad Med Sci, Dept Radiol, Guangzhou 510080, Guangdong, Peoples R China [2]Guangdong Gen Hosp, Guangdong Acad Med Sci, Dept Neurol, Guangzhou 510080, Guangdong, Peoples R China [3]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, Wuhan 430030, Hubei, Peoples R China
出处:
ISSN:

关键词: High resolution magnetic resonance imaging Atherosclerosis Plaque analysis Middle cerebral artery

摘要:
Purpose: To assess the reproducibility of HR-MRI for the identification of MCA atherosclerotic plaque components and quantification of stenosis. Materials and methods: Seventy-three consecutive subjects who initially had ischemic stroke or asymptomatic MCA stenosis (>50%) were enrolled in the study. All subjects were scanned using 3.0 T MRI. Two independent readers reviewed all images and one reader reevaluated all images four weeks later. The tissue components of plaques were analyzed qualitatively and the vessels were quantitative measured. Results: HR-MRI displayed the artery wall and lumen clearly. The intra-observer reproducibility was excellent for the identification of plaques (kappa [kappa] = 0.96; 95% CI: 0.83-1.04) and contrast enhancement (kappa = 0.89; 0.78-0.95); it was substantial for intra-plaque hemorrhage (kappa = 0.79; 0.57-0.96) and the fibrous cap (kappa = 0.65; 0.42-0.86). The inter-observer reproducibility was excellent for plaques (kappa = 0.92; 0.73-1.06), substantial for contrast enhancement (kappa = 0.80; 0.65-0.93), intra-plaque hemorrhage (kappa = 0.68; 0.47-0.92) and moderate for the fibrous cap (kappa = 0.58; 0.44-0.79). Both intra-observer and inter-observer reproducibility were excellent for quantitative vessel, lumen and wall measurements with intraclass correlation coefficients ranging from 0.91 to 0.97 and 0.87 to 0.96, respectively. However, vessel and wall areas and the intervals defined by the Bland-Altman plots were wide in comparison to the mean. Conclusions: The identification of MCA atherosclerotic plaque components and the quantification of vessel and lumen measurements are reproducible. The reproducibility is overall acceptable. HR-MRI may provide a useful tool for clinical risk evaluation in MCA atherosclerosis. (C) 2013 Elsevier Ireland Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2012]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者单位: [1]Guangdong Gen Hosp, Guangdong Acad Med Sci, Dept Radiol, Guangzhou 510080, Guangdong, Peoples R China
通讯作者:
通讯机构: [1]Guangdong Gen Hosp, Guangdong Acad Med Sci, Dept Radiol, Guangzhou 510080, Guangdong, Peoples R China [*1]Guangdong Gen Hosp, Guangdong Acad Med Sci, Dept Radiol, 106 Zhongshan 2nd Rd, Guangzhou 510080, Guangdong, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:428 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)