高级检索
当前位置: 首页 > 详情页

Clinical Study of Electro-acupuncture Treatment with Different Intensities for Functional Constipation Patients

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Inst Integrat Tradit Chinese & Western Med,Tongji Hosp,Tongji Med Coll,Wuhan 430030,Peoples R China
出处:
ISSN:

关键词: electro-acupuncture current intensity functional constipation quchi (LI11) shangjuxu (ST37)

摘要:
Functional constipation (FC) is a common functional bowel disorder disease that affects life quality of a large number of people. This study aimed to explore the impact of different intensities of electro-acupuncture (EA) treatment for FC patients. Totally, 111 patients with FC meeting the Rome. criteria were randomly assigned to different intensities of EA groups (low and high intensity of EA groups) and medicine-controlled (MC) group. In EA groups, patients were treated with EA at quchi (LI11) and shangjuxu (ST37) bilaterally for 4 weeks, 5 times/week in the first 2 weeks, and 3 times/week in the last 2 weeks. In MC group, 5 mg mosapride citrate was administered orally 3 times/day for 4 weeks. Spontaneous bowel movement frequency each day was recorded using a constipation diary. Self-rating anxiety scale (SAS) and self-rating depression scale (SDS) were used to assess the patients' psychological state. Cortisol (CORT), substance P (SP), and vasoactive intestinal polypeptide (VIP) were evaluated at baseline and at the end of 4 weeks after treatment. As compared with the baseline, there was statistically significant increase in stool frequency every week (P<0.01), but there was no statistically significant difference among the three groups. As compared with the baseline, after 4 weeks of EA therapy, the scores of SDS and serum levels of CORT were decreased significantly in low intensity of EA group (P<0.01), and the serum levels of SP and VIP were increased significantly (P<0.05); the scores of SAS and SDS and serum levels of CORT were decreased significantly in high intensity of EA group (P<0.05), and the serum levels of SP and VIP were increased significantly (P<0.05); the serum levels of CORT and VIP were increased significantly in MC group (P<0.05). As compared with MC group, after 4 weeks of treatment, the serum levels of SP were significantly increased in low intensity of EA group (P<0.01). Low and high intensities of EA could increase the stool frequency, improve the FC patient's anxiety and depression, reduce the serum levels of CORT, and increase the serum levels of SP and VIP effectively. It is concluded that both low and high intensities of EA are effective for FC patients, but there is no significant difference between the low and high intensities of EA.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 4 区 医学
小类 | 4 区 生化与分子生物学
最新[2025]版:
JCR分区:
出版当年[2012]版:
Q4 BIOCHEMISTRY & MOLECULAR BIOLOGY
最新[2023]版:

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Inst Integrat Tradit Chinese & Western Med,Tongji Hosp,Tongji Med Coll,Wuhan 430030,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:586 今日访问量:0 总访问量:441 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)