高级检索
当前位置: 首页 > 详情页

Studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Xinxiang Med Univ, Dept Histol & Embryol, Preclin Med Coll, Xinxiang, Henan, Peoples R China [2]Huazhong Univ Sci & Technol, Family Planning Res Inst, Tongji Med Coll, 13 Hangkong Rd, Wuhan 430030, Hubei, Peoples R China [3]Kunming Med Univ, Affiliated Hosp 1, Dept Reprod & Genet, Kunming, Yunnan, Peoples R China [4]Zhengzhou Univ, Affiliated Hosp 1, Dept Gynecol, Zhengzhou, Henan, Peoples R China [5]Taikang Tongji Hosp, Dept Obstet & Gynaecol, Wuhan, Hubei, Peoples R China [6]Dayu Med Devices Co Ltd, Jingzhou, Hubei, Peoples R China [7]Huazhong Univ Sci & Technol, Reprod Med Ctr, Tongji Med Coll, Wuhan, Hubei, Peoples R China
出处:
ISSN:

关键词: intrauterine device copper/low-density polyethylene nanocomposite intrauterine device acute toxicity subchronic toxicity

摘要:
Introduction: The physiologic safety of devices and materials intended for clinical implantation should be evaluated. This study, a logical extension of our previous work, aimed to investigate the safety of a novel contraceptive device, the copper/low-density polyethylene nanocomposite intrauterine device (nano-Cu/LDPE IUD), through studies of its potential toxicity after acute and subchronic administration in mice and rats. Methods: For the acute toxicity study, single 50 mL/kg doses of nano-Cu/LDPE IUD extracts were administered to mice via intravenous or intraperitoneal injection. General behavioral adverse effects, mortality, and body weights were evaluated for up to 72 hours. In the 13-week subchronic toxicity study, the nano-Cu/LDPE composite with 10-fold higher than the standard clinical dose was implanted subcutaneously into the dorsal skin of Wistar rats. The control group underwent a sham procedure without material insertion. Results: During all acute study observation times, the biologic reactions of the mice in the nano-Cu/LDPE group did not differ from those observed in the control group. The groups did not differ statistically in terms of body weight gain, and no macroscopic changes were observed in any organs. In the subchronic study, no clinical signs of toxicity or mortality were observed in either the nano-Cu/LDPE or control group during the 13-week period. The nano-Cu/LDPE composite did not cause any alterations in body weight, food consumption, hematologic and biochemical parameters, or organ weight relative to the control for any observed sample group. Histopathologic examinations of the organs revealed normal architecture, indicating that the inserted material did not cause morphologic disturbances in the rats. Conclusion: Overall, the results indicate that the nano-Cu/LDPE IUD did not induce systemic toxicity under experimental conditions of the recommended standard practices, suggesting that the novel material IUD is safe and feasible for future contraceptive applications.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 2 区 工程技术
小类 | 2 区 药学 3 区 纳米科技
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 药学 3 区 纳米科技
JCR分区:
出版当年[2016]版:
Q1 PHARMACOLOGY & PHARMACY Q2 NANOSCIENCE & NANOTECHNOLOGY
最新[2023]版:
Q1 NANOSCIENCE & NANOTECHNOLOGY Q1 PHARMACOLOGY & PHARMACY

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者单位: [1]Xinxiang Med Univ, Dept Histol & Embryol, Preclin Med Coll, Xinxiang, Henan, Peoples R China
通讯作者:
通讯机构: [2]Huazhong Univ Sci & Technol, Family Planning Res Inst, Tongji Med Coll, 13 Hangkong Rd, Wuhan 430030, Hubei, Peoples R China [7]Huazhong Univ Sci & Technol, Reprod Med Ctr, Tongji Med Coll, Wuhan, Hubei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:434 今日访问量:0 总访问量:416 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题