An open label, prospective, multicenter, non-interventional study of iodixanol 270 mg I/mL for use in individuals undergoing computed tomography angiography in real-world clinical practice

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Capital Med Univ, Xuanwu Hosp, Dept Radiol, Beijing, Peoples R China [2]Chinese Acad Med Sci, Fuwai Hosp, Peking Union Med Coll, Natl Ctr Cardiovasc Dis,Dept Radiol, Beijing, Peoples R China [3]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Hubei, Peoples R China [4]Sichuan Univ, West China Hosp, Dept Radiol, Chengdu, Sichuan, Peoples R China
出处:
ISSN:

关键词: Computed tomography angiography iodixanol image quality radiation dose

摘要:
Background: Concern about radiation exposure is leading to an increasing interest in low-concentration contrast medium administration. Purpose: To evaluate the image quality and safety profile after administration of iodixanol 270 mg I/mL at 100-kVp tube voltage with iterative reconstruction in subjects undergoing computed tomography angiography (CTA). Material and Methods: Patients who completed CTA examination using iodixanol 270 mg I/mL and 100-kVp tube voltage along with iterative reconstruction for coronary, aortic, head and neck, renal, or pulmonary arteries were included. Image quality was qualitatively and quantitatively evaluated. Incidence of adverse events (AEs) and adverse drug reactions (ADRs) within seven days and radiation dose were also analyzed. Results: A total of 4513 individuals in 42 centers in China were enrolled, among which 4367 were included in efficacy analysis. The mean image quality score was 4.8 +/- 0.45 across all arteries (all above 4.6) and 99.7% of the individuals' images were classified as evaluable. The CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the regions of interest (ROIs) were 431.79 +/- 99.018, 18.29 +/- 11.947, and 28.21 +/- 19.535 HU, respectively. Of all the participants, 68 (1.5%) and 65 (1.4%) experienced AEs and ADRs, respectively. No serious AEs or AEs leading to discontinuation occurred. The average effective radiation dose was 3.13 +/- 2.550 mSv. Conclusion: Iodixanol 270 mg I/mL in combination with 100-kVp tube voltage and iterative reconstruction could be safely applied in CTA and yield high-quality and evaluable images with reduced radiation dose.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2017]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者单位: [1]Capital Med Univ, Xuanwu Hosp, Dept Radiol, Beijing, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

[1]Impact of coronary computed tomography angiography-derived fractional flow reserve based on deep learning on clinical management [2]多层螺旋CT肺静脉成像质量与辐射剂量控制研究 [3]Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake [4]Prospective Study of Low- and Standard-dose Chest CT for Pulmonary Nodule Detection: A Comparison of Image Quality, Size Measurements and Radiation Exposure [5]High spatial resolution time-resolved magnetic resonance angiography of lower extremity tumors at 3T: Comparison with computed tomography angiography [6]Histogram analysis with computed tomography angiography for discriminating soft tissue sarcoma from benign soft tissue tumor [7]The diagnostic value of time-resolved MR angiography with Gadobutrol at 3 T for preoperative evaluation of lower extremity tumors: Comparison with computed tomography angiography [8]The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography Effects on image quality and radiation dose [9]Retraction notice to "The diagnostic value of time-resolved MR angiography with Gadobutrol at 3T for preoperative evaluation of lower extremity tumors: Comparison with computed tomography angiography". [10]Preliminary clinical application of an adaptive iterative statistical reconstruction algorithm inhead and neck computed tomography angiography with low tube voltage and a low concentration of contrast medium

资源点击量:426 今日访问量:0 总访问量:408 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)