Prospective Study of Low- and Standard-dose Chest CT for Pulmonary Nodule Detection: A Comparison of Image Quality, Size Measurements and Radiation Exposure

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 卓越:梯队期刊

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China [2]Southern Med Univ, Shenzhen Matern & Child Healthcare Hosp, Dept Radiol, Shenzhen 518028, Peoples R China
出处:
ISSN:

关键词: pulmonary nodules tomography X-ray computed radiation dosage lung breast

摘要:
Objective To comprehensively and accurately analyze the out-performance of low-dose chest CT (LDCT) vs. standard-dose CT (SDCT). Methods The image quality, size measurements and radiation exposure for LDCT and SDCT protocols were evaluated. A total of 117 patients with extra-thoracic malignancies were prospectively enrolled for non-enhanced CT scanning using LDCT and SDCT protocols. Three experienced radiologists evaluated subjective image quality independently using a 5-point score system. Nodule detection efficiency was compared between LDCT and SDCT based on nodule characteristics (size and volume). Radiation metrics and organ doses were analyzed using Radimetrics. Results The images acquired with the LDCT protocol yielded comparable quality to those acquired with the SDCT protocol. The sensitivity of LDCT for the detection of pulmonary nodules (n=650) was lower than that of SDCT (n=660). There was no significant difference in the diameter and volume of pulmonary nodules between LDCT and SDCT (for BMI <22 kg/m(2), 4.37 vs. 4.46 mm, and 43.66 vs. 46.36 mm(3); for BMI >= 22 kg/m(2), 4.3 vs. 4.41 mm, and 41.66 vs. 44.86 mm(3)) (P>0.05). The individualized volume CT dose index (CTDIvol), the size specific dose estimate and effective dose were significantly reduced in the LDCT group compared with the SDCT group (all P<0.0001). This was especially true for dose-sensitive organs such as the lung (for BMI <22 kg/m(2), 2.62 vs. 12.54 mSV, and for BMI >= 22 kg/m(2), 1.62 vs. 9.79 mSV) and the breast (for BMI <22 kg/m(2), 2.52 vs. 10.93 mSV, and for BMI >= 22 kg/m(2), 1.53 vs. 9.01 mSV) (P<0.0001). Conclusion These results suggest that with the increases in image noise, LDCT and SDCT exhibited a comparable image quality and sensitivity. The LDCT protocol for chest scans may reduce radiation exposure by about 80% compared to the SDCT protocol.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2019]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)