高级检索
当前位置: 首页 > 详情页

Cytotoxicity and the Effect of Temperature on Physical Properties and Chemical Composition of a New Calcium Silicate-based Root Canal Sealer

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Univ British Columbia, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China [2]Univ British Columbia, Fac Dent, Dept Oral Biol & Med Sci, Div Endodont, 2199 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada [3]Univ British Columbia, Dept Mat Engn, Vancouver, BC, Canada [4]Coll & Hosp Stomatol, Dept Operat Dent & Endodontol, Nanning, Guagnxi, Peoples R China
出处:
ISSN:

关键词: Cell viability EndoSequence BC sealer Fourier-transform infrared spectroscopy HiFlow physical properties warm vertical compaction

摘要:
Introduction: The suitability of EndoSequence BC Sealer (BC Sealer; Brasseler USA, Savannah, GA) for warm vertical compaction has been questioned. The aim was to evaluate the cytotoxicity and the effect of heating on the physicochemical properties of a new calciumbased root canal sealer (EndoSequence BC Sealer HiFlow [HiFlow]) in comparison with EndoSequence BC Sealer. Methods: Human periodontal ligament fibroblasts were incubated for 1, 2, or 3 days with material extracts of different concentrations, and cell viability was evaluated by Cell Counting Kit-8 (Enzo Life Sciences Inc, Burlington, Ontario, Canada). The setting time, flow, film thickness, microhardness, radiopacity, and radiopacity of the 2 sealers were measured according to ISO 6786/2012. The continuous changes in viscosity were tested by a stress-controlled rheometer at shear rates ranging from 0.01-10 s(-1) and different temperatures, and chemical composition was assessed by Fourier-transform infrared spectroscopy. Results: Cell viability was significantly decreased on day 3 for the 1:4 diluted extract from both materials. The setting time, microhardness, and solubility of HiFlow were similar to BC Sealer at 37 degrees C and 100 degrees C. HiFlow had significantly higher flow and radiopacity than BC Sealer at room temperature (P < .05), and when heated, HiFlow retained its higher flow and lower film thickness (P < .05). Both sealers showed decreasing viscosity with increasing shear rate, and at a shear rate of 0.01 and 0.1 s(-1), HiFlow exhibited lower viscosity than BC Sealer at all temperatures measured. The chemical composition of the 2 sealers was not changed by heating. Conclusions: HiFlow showed better performance on flow/viscosity and film thickness, especially under high temperatures, which are generated by the commonly used warm vertical compaction technique.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 医学
小类 | 2 区 牙科与口腔外科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 牙科与口腔外科
JCR分区:
出版当年[2018]版:
Q1 DENTISTRY, ORAL SURGERY & MEDICINE
最新[2023]版:
Q1 DENTISTRY, ORAL SURGERY & MEDICINE

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Univ British Columbia, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China [2]Univ British Columbia, Fac Dent, Dept Oral Biol & Med Sci, Div Endodont, 2199 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Univ British Columbia, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China [2]Univ British Columbia, Fac Dent, Dept Oral Biol & Med Sci, Div Endodont, 2199 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:428 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)