Micro-computed tomography analysis of calcium hydroxide delivery efficacy in C-shaped canal system of mandibular second molars

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]State Key Laboratory of Oral Diseases, Department of Cariology and Endodontics, West China Hospital of Stomatology, National Clinical Research Center for Oral Diseases, Sichuan University, 14# 3rd Section, Renmin South Road, Chengdu, Sichuan Province, 610041, China. [2]Department of Stomatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, Hubei Province, 430030, China. [3]School of Stomatology, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
出处:
ISSN:

关键词: Calcium hydroxide C-shaped canal Delivery efficacy Mandibular second molars Micro-CT

摘要:
Calcium hydroxide [Ca(OH)2] is widely accepted as a biocompatible interappointment intracanal medicament. This study aimed to analyze the efficacy of Ca(OH)2 placement into the C-shaped canal system of mandibular second molars using the syringe method with and without lentulo spiral utilizing micro-computed tomography (micro-CT).Twenty-four extracted mandibular second molars were instrumented and classified into C-shaped floors (n = 12) and non-C-shaped floors (n = 12). Both groups were placed with Ca(OH)2 using the syringe system, then all teeth were scanned and cleaned, and placed with Ca(OH)2 again but with the syringe system followed by lentulo spiral and rescanned. The specimens were scanned using micro-CT to analyze the volume, volume percentage, uncontacted surface area, and uncontacted surface area percentage of Ca(OH)2 with the two delivery methods in the entire canal and at the apical 4 mm of the canal. Mann-Whitney test and Wilcoxon signed-rank test were used to determine the statistical differences among the groups.Syringe administration used in conjunction with lentulo spiral presented lower uncontacted surface area, a lower percentage of uncontacted surface area, larger volume, and a higher percentage of volume than syringe without lentulo spiral (P < 0.05). There was no significant difference between the C-shaped floor group and the non-C-shaped floor group (P > 0.05) in the Ca(OH)2 uncontacted surface area, volume, and percentages at different regions of canals and among different delivery techniques groups.The lentulo spiral and syringe technique combination can increase the volume and contacted surface area of Ca(OH)2 in the C-shaped canal system of mandibular second molars.© 2023. The Author(s).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 2 区 牙科与口腔外科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 牙科与口腔外科
JCR分区:
出版当年[2022]版:
Q2 DENTISTRY, ORAL SURGERY & MEDICINE
最新[2023]版:
Q1 DENTISTRY, ORAL SURGERY & MEDICINE

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者单位: [1]State Key Laboratory of Oral Diseases, Department of Cariology and Endodontics, West China Hospital of Stomatology, National Clinical Research Center for Oral Diseases, Sichuan University, 14# 3rd Section, Renmin South Road, Chengdu, Sichuan Province, 610041, China.
共同第一作者:
通讯作者:
通讯机构: [2]Department of Stomatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, Hubei Province, 430030, China. [3]School of Stomatology, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:590 今日访问量:1 总访问量:442 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)