高级检索
当前位置: 首页 > 详情页

Quantitative evaluation of the spinal cord compression in patients with cervical spondylotic myelopathy using synthetic MRI

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology,Tongji Hospital Affiliated to Tongji Medical College,Huazhong University of Science and Technology,Wuhan,China. [2]Department of Orthopedics,Tongji Hospital Affiliated to Tongji Medical College,Huazhong University of Science and Technology,Wuhan,China. [3]MR Research, GE Healthcare, Beijing, China. [4]Department of Urology,Tongji Hospital Affiliated to Tongji Medical College,Huazhong University of Science and Technology,Wuhan,China.
出处:
ISSN:

关键词: magnetic resonance image synthetic quantitative evaluation spinal cord cervical spondylotic myelopathy

摘要:
Objectives: This work aimed to investigate the feasibility and diagnostic value of synthetic MRI, including T1, T2 and PD values in determining the severity of cervical spondylotic myelopathy (CSM). Methods: All subjects (51 CSM patients and 9 healthy controls) underwent synthetic MRI scan on a 3.0T GE MR scanner. The cervical canal stenosis degree of subjects was graded 0-III based on the method of a MRI grading system. Regions of interest (ROIs) were manually drawn at the maximal compression level (MCL) by covering the whole spinal cord to generate T1MCL, T2MCL, and PDMCL values in grade I-III groups. Besides, anteroposterior (AP) and transverse (Trans) diameters of the spinal cord at MCL were measured in grade II and grade III groups, and relative values were calculated as follows: rAP = APMCL/APnormal, rTrans = TransMCL/Transnormal. rMIN = rAP/rTrans. Results: T1MCL value showed a decreasing trend with severity of grades (from grade 0 to grade II, p < 0.05), while it increased dramatically at grade III. T2MCL value showed no significant difference among grade groups (from grade 0 to grade II), while it increased dramatically at grade III compared to grade II (p < 0.05). PDMCL value showed no statistical difference among all grade groups. rMIN of grade III was significantly lower than that of grade II (p < 0.05). T2MCL value was negatively correlated with rMIN, whereas positively correlated with rTrans. Conclusion: Synthetic MRI can provide not only multiple contrast images but also quantitative mapping, which is showed promisingly to be a reliable and efficient method in the quantitative diagnosis of CSM.Copyright © 2023 Liu, Shao, Liu, Liu, Saeed, Zhang, Lu, Zhang, Li, Tang, Du and Zhu.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 医学
小类 | 2 区 生理学
最新[2025]版:
大类 | 3 区 医学
小类 | 2 区 生理学
JCR分区:
出版当年[2021]版:
Q1 PHYSIOLOGY
最新[2023]版:
Q2 PHYSIOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者单位: [1]Department of Radiology,Tongji Hospital Affiliated to Tongji Medical College,Huazhong University of Science and Technology,Wuhan,China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:586 今日访问量:0 总访问量:441 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)