高级检索
当前位置: 首页 > 详情页

Effect of ultrasound angle for radial artery cannulation in adults: a randomized controlled trial

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Anesthesiol, Jiefang ave 1095, Wuhan, Peoples R China [2]Sichuan Acad Med Sci & Sichuan Prov Peoples Hosp, Dept Anesthesiol, Chengdu, Peoples R China
出处:
ISSN:

关键词: Ultrasonography Needles Catheterization

摘要:
BACKGROUND: Although the first attempt success rate of radial artery cannulation has been significantly improved by using dynamic needle tip positioning (DNTP) method, there are still problems with long cannulation time. We hereby observe the effect of ultrasound angle for radial artery cannulation in adult patients. METHODS: Adult patients scheduled to undergo elective surgeries with continuous invasive blood pressure monitoring were included and randomly allocated into either a U-P-artery (ultrasound probe perpendicular to the artery) or U-P needle (ultrasound probe perpendicular to the needle) group. The primary outcome measure was cannulation time at the first attempt, the secondary outcome measures included the first attempt success rate, number of attempts and the total puncture procedure duration. In addition, the incidence of complications was included as secondary outcomes. RESULTS: Fifty-nine patients were evaluated finally. The cannulation time at the first attempt in U-P-needle group (N.=28) was significantly lower than that in U-P-artery group (N.=31; median [IQR]: 16 [13.5-20] seconds vs. 41 [25.554.5] seconds, P<0.001). The total puncture procedure duration in group U-P-needle was also shorter than that in the group U-P-artery (median [IQR]: 17.4 [13.5-20] seconds vs. 52.2 [25.5-54.5] seconds, P<0.001). No significant difference was observed with respect to first-attempt success rate (96.4% vs. 93.5%, relative risk: 0.97, 95% CI: 0.863-1.0907, P=0.615). The number of attempts showed no statistical difference as well. CONCLUSIONS: The usage of the U-P-needle approach could remarkably reduce radial arterial cannulation time at the first attempt as well as total puncture procedure duration, comparing with the U-P-artery approach. (Cite this article as: Zhang S, Liu T, Liu Y, Mei W. Effect of ultrasound angle for radial artery cannulation in adults: a randomized controlled trial. Minerva Anestesiol 2022;88:230-7. DOI: 10.23736/S0375-9393.22.16090-6)

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 麻醉学 4 区 危重病医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 麻醉学 4 区 危重病医学
JCR分区:
出版当年[2020]版:
Q3 ANESTHESIOLOGY Q3 CRITICAL CARE MEDICINE
最新[2023]版:
Q1 ANESTHESIOLOGY Q2 CRITICAL CARE MEDICINE

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Anesthesiol, Jiefang ave 1095, Wuhan, Peoples R China [2]Sichuan Acad Med Sci & Sichuan Prov Peoples Hosp, Dept Anesthesiol, Chengdu, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)