Background: A lack of high-quality research and data has restricted the comprehensive understanding of the conversion procedure of convertible inferior vena cava filters. The aim of this study was to present an unusual situation with a high risk of causing complication, during conversion of VenaTech convertible inferior vena cava filter and our management procedure. Methods: Lower extremity deep venous thrombi were detected in a 62-year-old woman before major orthopedic surgery. A VenaTech convertible inferior vena cava filter was placed to prevent possible pulmonary embolism and 106 days later, the filter was converted without any complications. Results: At the 6-month follow-up, no adverse events were reported. Conclusions: The long-term indwelling of a filter might increase the complexity and uncertainty of the conversion procedure. This report presented a rare but hazardous situation during conversion and our management procedure.
第一作者单位:[1]Huazhong Univ Sci & Technol, Div Vasc Surg, Hepat Surg Ctr, Tongji Hosp,Tongji Med Coll, 1095 Jiefang Ave, Wuhan 430030, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
Li Tao,Dong Shuilin,Zhang Zhiwei,et al.Hazardous Situation During Conversion of a Long-term Indwelling VenaTech Convertible Inferior Vena Cava Filter[J].ANNALS OF VASCULAR SURGERY.2021,76:doi:10.1016/j.avsg.2021.04.041.
APA:
Li, Tao,Dong, Shuilin,Zhang, Zhiwei&Yang, Jun.(2021).Hazardous Situation During Conversion of a Long-term Indwelling VenaTech Convertible Inferior Vena Cava Filter.ANNALS OF VASCULAR SURGERY,76,
MLA:
Li, Tao,et al."Hazardous Situation During Conversion of a Long-term Indwelling VenaTech Convertible Inferior Vena Cava Filter".ANNALS OF VASCULAR SURGERY 76.(2021)