高级检索
当前位置: 首页 > 详情页

Comparison of reduced field-of-view diffusion-weighted imaging (DWI) and conventional DWI techniques in the assessment of Cervical carcinoma at 3.0T: Image quality and FIGO staging

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, 1095 Jiefang Ave, Wuhan 430030, Hubei, Peoples R China
出处:
ISSN:

关键词: Diffusion-weighted imaging Full field-of-view Cervical carcinoma Image quality Reduced field-of-view

摘要:
Objective: To evaluate imaging quality (IQ) and International Federation of Gynecology and Obstetrics (FIGO) staging of reduced field-of-view (r-FOV) diffusion-weighted imaging (DWI) in cervical carcinoma (CC). Materials and methods: Sixty patients with pathologically proven CC who underwent both pre-treatment r-FOV DWI and full field-of-view (f-FOV) DWI on a 3.0T MRI scanner were retrospectively reviewed. The subjective qualitative image scores were compared using the Wilcoxon signed-rank test. Objective quality values and apparent diffusion coefficient (ADC) were estimated by paired t-test or Wilcoxon signed-rank test for the two DWI sequences according to Normality test. Spearman rank correlation analysis was used to evaluate the relationship between pathological results and mean ADC value. Results: The subjective IQ scores for r-FOV DWI were significantly higher than those for f-FOV DWI (P < 0.001). Similarly, the contrast-to-noise (CNR) value of r-FOV DWI was superior to that of f-FOV DWI (10.30 +/- 3.676, 8.91 +/- 3.008, P = 0.021). However, the signal-to-noise ratio (SNR) value of r-FOV DWI was considerably lower than that of f-FOV DWI (27.80 +/- 6.056, 33.67 +/- 7.833, P<0.001). No significant difference was found between mean ADC values of f-FOV DWI and r-FOV DWI. There was a significant tendency for a negative correlation between the ADC values and FIGO stages of CC for both two sequences (r=-0. 436, P<0.01; r=-0.470, P<0.01, respectively). Conclusions: The rFOV DWI sequence provided significantly better IQ and lesion conspicuity than the fFOV DWI sequence. In addition, rFOV sequences can be used in evaluation of FIGO staging of cervical cancer.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2019]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, 1095 Jiefang Ave, Wuhan 430030, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:428 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)