高级检索
当前位置: 首页 > 详情页

The usability of ventilator maintenance user interface: A comparative evaluation of user task performance, workload, and user experience

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ SSCI

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Med Equipment, Tongji Med Coll, 1095 JieFang Ave, Wuhan 430030, Peoples R China
出处:
ISSN:

关键词: Critical care equipment design eye movement measurements ventilator user computer interface

摘要:
Poor usability designed of ventilator user interface can easily lead to human error. In this study, we evaluated the usability design of ventilator maintenance user interface and identified problems related to the usability of user interface that could easily cause human error. Sixteen respiratory therapists participated in this usability study. The usability of the ventilator maintenance user interface was evaluated by participants' task performance (task completion time, task error rate), physiological workload (eye-fixation duration) and perceived workload (NASA-TLX), and user experience (questionnaire). For task performance, task completion time and task error rate showed significant differences. For task completion time, significant difference was found when conducting ventilator self-test (p < 0.001), replace the breathing circuit (p = 0.047), and check battery status (p = 0.005). For task error rate, the three ventilators showed significant difference (p = 0.012), and the Serov I showed a significantly higher task error rate than the Boaray 5000D (p = 0.031). For workload, the Serov I was associated with higher physiological and perceived workloads than other ventilators (p < 0.05). For user experience, the Boaray 5000D received better scores among the ventilators in terms of ease to maintain, friendly to maintain, and willingness to use (p < 0.05, respectively). Our study adds available literature for usability evaluation of ventilator maintenance user interface. The results indicate that the maintenance user interface of the Boaray 5000D performed better than the other two tested ventilators. Moreover, the study results also proved that eye-fixation duration can be a reliable tool for evaluating the usability of ventilator user interface.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 综合性期刊
小类 | 4 区 综合性期刊
最新[2025]版:
大类 | 4 区 综合性期刊
小类 | 4 区 综合性期刊
JCR分区:
出版当年[2018]版:
Q3 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q2 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Med Equipment, Tongji Med Coll, 1095 JieFang Ave, Wuhan 430030, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)