Intraprocedural and Long-Term Incomplete Occlusion of the Left Atrial Appendage Following Placement of the WATCHMAN Device: A Single Center Experience

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX 78705 USA [2]Huazhong Univ Sci & Technol, Tong Ji Hosp, Dept Internal Med, Tong Ji Med Coll, Wuhan 430074, Hubei, Peoples R China [3]Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA [4]Univ Foggia, Dept Cardiol, Foggia, Italy [5]Univ Chile, Hosp Clin, Santiago, Chile [6]Stanford Univ, Div Cardiol, Palo Alto, CA 94304 USA [7]Scripps Clin, San Diego, CA USA [8]Case Western Reserve Univ, Sch Med, Cleveland, OH USA
出处:
ISSN:

关键词: atrial fibrillation closure left atrial appendage stroke thrombus WATCHMAN device

摘要:
Incomplete LAA Occlusion by WATCHMAN Device. Introduction: Transcatheter left atrial appendage (LAA) closure with the WATCHMAN device has become one of the therapeutic options in atrial fibrillation (AF) patients who are at high risk for ischemic stroke. However, the incidence and evolution of incomplete occlusion of the LAA during and after placement of the WATCHMAN device has not been reported. Methods and Results: Fifty-eight consecutive patients who had undergone WATCHMAN device implant were included in the study. Intraprocedural, 45-day and 12-month transesophageal echocardiogram images were reviewed and analyzed. Peridevice gap was noted in 16 (27.6%), 17 (29.3%), and 20 (34.5%) patients across the 3 time points. Intraprocedural gaps are more likely to be persistent until 12 months and become larger in size over time. New gap also occurs during follow-up even if the LAA was completely sealed at implantation. One patient had an ischemic stroke 4.7 months after implant; another patient developed a left atrial thrombus over the device 21.6 months after implant. Both patients had intraprocedural gap and discontinued warfarin therapy after the 45-day evaluation. Conclusion: Incomplete LAA occlusion with a gap between the WATCHMAN device surface and the LAA wall is relatively common. Intraprocedural gaps are more likely to become bigger over time and persist, while new gaps also occur during follow-up. Further studies are warranted to verify whether the presence and persistence of a peridevice gap is associated with increased risk of thromboembolic event in AF patients implanted with a WATCHMAN device. (J Cardiovasc Electrophysiol, Vol. 23, pp. 455-461, May 2012)

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 2 区 医学
小类 | 3 区 心脏和心血管系统
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 心脏和心血管系统
JCR分区:
出版当年[2010]版:
Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q2 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者单位: [1]St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX 78705 USA [2]Huazhong Univ Sci & Technol, Tong Ji Hosp, Dept Internal Med, Tong Ji Med Coll, Wuhan 430074, Hubei, Peoples R China
通讯作者:
通讯机构: [1]St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX 78705 USA [3]Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA [6]Stanford Univ, Div Cardiol, Palo Alto, CA 94304 USA [7]Scripps Clin, San Diego, CA USA [8]Case Western Reserve Univ, Sch Med, Cleveland, OH USA [*1]St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, 3000 N I-35,Suite 720, Austin, TX 78705 USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:590 今日访问量:0 总访问量:442 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)