高级检索
当前位置: 首页 > 详情页

Circulating MicroRNAs as Biomarkers in Hepatocellular Carcinoma Screening A Validation Set From China

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Affiliated Tongji Hosp,Dept Biliary & Pancreat Surg,Tongji Med Coll,Wuhan 430030,Peoples R China [2]Huazhong Univ Sci & Technol,Affiliated Tongji Hosp,Hepat Surg Ctr,Tongji Med Coll,Wuhan 430030,Peoples R China [3]Vanderbilt Univ, Sch Med, Dept Med, Nashville, TN 37212 USA [4]Vanderbilt Univ, Sch Med, Dept Canc Biol, Nashville, TN 37212 USA
出处:
ISSN:

摘要:
Hepatocellular carcinoma (HCC) is a global public health concern. Current diagnostic methods show poor performance in early-stage HCC detection. Accumulating evidences revealed the great potential of microRNAs (miRNAs) as noninvasive biomarkers in HCC detection. In this study, we examined the diagnostic performance of serum miR-10b, miR-106b, and miR-181a for HCC screening in China. Furthermore, a systematic review of previous related studies was conducted to confirm our results. One hundred eight participants including 27 HCC patients, 31 chronic liver disease (CLD) patients, and 50 healthy people were recruited in this study. Blood specimen was drawn from each participant to extract serum miRNAs. Statistical analyses were performed to assess the 3 miRNAs levels in HCC, CLD patients, and normal controls. A meta-analysis was conducted to further assess the diagnostic value of miRNAs in HCC detection based on previous studies. All these miRNAs (miR-10b, miR-181a, miR-106b) could well discriminate HCC patients from normal controls, with area under the receiver-operating characteristic curve (AUC) values of 0.85 (95% confidence interval [CI]: 0.76-0.94), 0.82 (95% CI: 0.72-0.91), and 0.89 (95% CI: 0.81-0.97), respectively. In addition, these miRNAs could distinguish HCC cases from CLD controls with a medium accuracy. However, the ability of these miRNAs in differentiating CLD patients from normal controls was not satisfactory. Panel of these miRNAs displayed a better performance compared with single miRNA assay, with AUC values of 0.94 (95% CI: 0.89-0.99) in discriminating HCC patients from normal controls and 0.91 (95% CI: 0.80-0.97) in discriminating HCC patients from CLD controls. Results of meta-analysis of previous studies combined with the current study suggested that circulating miRNAs could well differentiate HCC from normal controls, with AUC values of 0.86 (95% CI: 0.82-0.89) for single miRNA assay and 0.94 (95% CI: 0.91-0.96) for miRNA panel assay. Serum miR-10b, miR-106b, and miR-181a have great potential to serve as accurate and noninvasive biomarkers for HCC preliminary screening. Meta-analysis of previous studies combined with current study further confirmed that circulating miRNAs could play an important role in HCC detection. Further large-scale studies are needed to confirm the clinical significance of circulating miRNAs in HCC screening.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2013]版:
Q1 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q2 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Affiliated Tongji Hosp,Dept Biliary & Pancreat Surg,Tongji Med Coll,Wuhan 430030,Peoples R China [*1]Huazhong Univ Sci & Technol,Affiliated Tongji Hosp,Dept Biliary & Pancreat Surg,Tongji Med Coll,1095 Jiefang St,Wuhan 430030,Peoples R China
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol,Affiliated Tongji Hosp,Dept Biliary & Pancreat Surg,Tongji Med Coll,Wuhan 430030,Peoples R China [*1]Huazhong Univ Sci & Technol,Affiliated Tongji Hosp,Dept Biliary & Pancreat Surg,Tongji Med Coll,1095 Jiefang St,Wuhan 430030,Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:1 总访问量:414 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)