DIAGNOSTIC POWER OF LONGITUDINAL STRAIN AT REST FOR THE DETECTION OF OBSTRUCTIVE CORONARY ARTERY DISEASE IN PATIENTS WITH TYPE 2 DIABETES MELLITUS

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Cardiol, Tongji Hosp, Wuhan 430030, Peoples R China
出处:
ISSN:

关键词: Speckle tracking imaging Strain Type 2 diabetes mellitus Coronary artery disease Myocardial ischemia

摘要:
Global longitudinal strain (GLS) measured by 2-D speckle-tracking echocardiography (2-D STE) at rest has been recognized as a sensitive parameter in the detection of significant coronary artery disease (CAD). However, the diagnostic power of 2-D STE in the detection of significant CAD in patients with diabetes mellitus is unknown. Two-dimensional STE features were studied in total of 143 consecutive patients who underwent echocardiography and coronary angiography. Left ventricular global and segmental peak systolic longitudinal strains (PSLSs) were quantified by speckle-tracking imaging. In the presence of obstructive CAD (defined as stenosis >= 75%), global PSLS was significantly lower in patients with diabetes mellitus than in patients without (16.65 +/- 2.29% vs. 17.32 +/- 2.27%, p, 0.05). Receiver operating characteristic analysis revealed that global PSLS could effectively detect obstructive CAD in patients without diabetes mellitus (cutoff value: -18.35%, sensitivity: 78.8%, specificity: 77.5%). However, global PSLS could detect obstructive CAD in diabetic patients at a lower cutoff value with inadequate sensitivity and specificity (cutoff value: -17.15%; sensitivity: 61.1%, specificity: 52.9%). In addition, the results for segmental PSLS were similar to those for global PSLS. In conclusion, global and segmental PSLSs at rest were significantly lower in patients with both obstructive CAD and diabetes mellitus than in patients with obstructive CAD only; thus, PSLSs at rest might not be a useful parameter in the detection of obstructive CAD in patients with diabetes mellitus. (C) 2015World Federation for Ultrasound in Medicine & Biology.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 3 区 医学
小类 | 2 区 声学 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 声学 3 区 核医学
JCR分区:
出版当年[2013]版:
Q1 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Cardiol, Tongji Hosp, Wuhan 430030, Peoples R China
通讯作者:
通讯机构: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Cardiol, Tongji Hosp, Wuhan 430030, Peoples R China [*1]Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Cardiol, Tongji Hosp, 1095 Jiefang Ave, Wuhan 430030, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

[1]The effect of type 2 diabetes mellitus on multiple obstructive coronary artery disease [2]RAPIDLY AND ACCURATELY DETECTING SIGNIFICANT CORONARY ARTERY STENOSIS IN PATIENTS WITH SUSPECTED STABLE CORONARY ARTERY DISEASE AND NORMAL SEGMENTAL WALL MOTION BY SPECKLE TRACKING AUTOMATED FUNCTIONAL IMAGING [3]RAPIDLY AND ACCURATELY DETECTING SIGNIFICANT CORONARY ARTERY STENOSIS IN PATIENTS WITH SUSPECTED STABLE CORONARY ARTERY DISEASE AND NORMAL SEGMENTAL WALL MOTION BY SPECKLE TRACKING AUTOMATED FUNCTIONAL IMAGING [4]PPARγ gene C161T substitution alters lipid profile in Chinese patients with coronary artery disease and type 2 diabetes mellitus [5]The Systolic and Diastolic Cardiac Function of Patients With Type 2 Diabetes Mellitus: An Evaluation of Left Ventricular Strain and Torsion Using Conventional and Speckle Tracking Echocardiography [6]The Systolic and Diastolic Cardiac Function of Patients With Type 2 Diabetes Mellitus: An Evaluation of Left Ventricular Strain and Torsion Using Conventional and Speckle Tracking Echocardiography. [7]应变超声对单纯及合并冠心病的2型糖尿病左室功能的评价 [8]Post-systolic shortening is superior to global longitudinal strain in predicting adverse events in patients with stable coronary artery disease and preserved systolic function [9]应变超声对单纯及合并冠心病的2型糖尿病左室功能的评价 [10]Widespread myocardial dysfunction in COVID-19 patients detected by myocardial strain imaging using 2-D speckle-tracking echocardiography