高级检索
当前位置: 首页 > 详情页

Exploring the impact of EGFR T790M neighboring SNPs on ARMS-based T790M mutation assay

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Inst Pathol,Tongji Hosp,Tongji Med Coll,1095 Jiefang Da Dao,Wuhan 430030,Hubei,Peoples R China
出处:
ISSN:

关键词: non-small cell lung cancer epidermal growth factor receptor gene T790M mutation amplification refractory mutation system single nucleotide polymorphism rs1050171

摘要:
The present study aimed to explore the influence of T790M neighboring single nucleotide polymorphism (SNP) on the sensitivity of amplification refractory mutation system (ARMS)-based T790M mutation assay. Three ARMS-quantitative polymerase chain reaction (qPCR) systems (system 1 had a forward ARMS primer without rs1050171, system 2 included a forward ARMS primer with rs1050171 and system 3 contained the above two forward ARMS primers) were used to detect the T790M mutation in two series plasmid samples and genomic DNA (gDNA) of the cell line H1975. A total of 670 formalin-fixed paraffin-embedded (FFPE) tumor samples from non-small cell lung cancer patients were used to detect the epidermal growth factor receptor (EGFR) gene T790M mutation by direct sequencing and ARMS-qPCR. The ARMS-qPCR system 1 effectively detected samples with as low as 1% T790M mutant plasmid 1 (without rs1050171) and with 50% T790M mutant plasmid 2 (with rs1050171), while the ARMS-qPCR system 2 detected samples with 20 and 50% T790M mutant plasmid 1, in addition to samples with 1% T790M mutant plasmid 2. For the ARMS-qPCR system 3, samples with as low as 1% T790M mutant plasmids 1 or 2 were effectively detected. For gDNA analysis of the cell line H1975, the T790M mutation was effectively detected by the ARMS-qPCR systems 2 and 3 (similar to 50% mutation rate), but was detected with a low mutation abundance by the ARMS-qPCR system 1 (similar to 1% mutation rate). Of the 670 FFPE samples, 5 cases were identified to have the T790M mutation by sequencing and by the ARMS-qPCR system 1. One sample (named N067), which was considered as T790M-negative by sequencing, was demonstrated to have the T790M mutation using the ARMS-qPCR system 1. Sample N094, which was variant homozygous for rs1050171 and was indicated to be T790M-negative by sequencing and by the ARMS-qPCR system 1, was identified to have the T790M mutation with the ARMS-qPCR system 3. The A-variant allele frequency of rs1050171 was observed to be 28.2% in the 670 FFPE tumor samples, while the presence of rs148188503 (c. C2355T, p. T785T) was observed in sample N558, and a novel SNP with a base substitution (c. T2375C) at position 792 (p. L792P) in exon 20 of the EGFR gene was observed in sample N310. rs1050171 is a high-frequency SNP located near T790M, and the mutation statuses of rs1050171 appear to influence the sensitivity of the ARMS-based T790M detection system, thus generating a 14.3% false-negative rate (1/7). The present study proposes the risk that target neighboring SNPs (as far as 8 bp away in the present study) may exert on the sensitivity of ARMS-based detection methods.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学
JCR分区:
出版当年[2014]版:
Q4 ONCOLOGY
最新[2023]版:
Q3 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Inst Pathol,Tongji Hosp,Tongji Med Coll,1095 Jiefang Da Dao,Wuhan 430030,Hubei,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:0 总访问量:408 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题