单位: [1]Mayo Clin, Dept Orthoped Surg, Rochester, MN USA [2]Huazhong Univ Sci & Technol,Tongji Hosp,Dept Orthoped,Tongji Med Coll,Wuhan,Peoples R China [3]Mayo Clin, Biomed Imaging Resource, Rochester, MN USA [4]Mayo Clin, Dept Physiol & Biomed Engn, 200 First St SW, Rochester, MN 55905 USA
出处:
ISSN:

摘要:
The spine is the most common site for secondary bone metastases, and clinical management for fractures is based on size and geometry of the defect. About 75% of the bone needs to be damaged before lesions are detectable, so clinical tools should measure changes in both geometry and material properties. Wehave developed an automated, user-friendly, Spine Cancer Assessment (SCA) image-based analysis method that builds on a platform designed for clinical practice providing failure characteristics of vertebrae. The objectives of this study were to (1) validate SCA predictions with experimental failure load outcomes; (2) evaluate the planning capabilities for prophylactic vertebroplasty procedures; and (3) investigate the effect of computed tomography (CT) protocols on predicted failure loads. Twenty-one vertebrae were randomly divided into two groups: (1) simulated defect without treatment (negative control) [n = 9] and (2) with treatment [n = 12]. Defects were created and a polymeric biomaterial was injected into the vertebrae in the treated-defect group. Spines were scanned, reconstructed with two algorithms, and analyzed for fracture loads. To virtually plan for prophylactic intervention, vertebrae with empty lesions were simulated to be augmented with either poly(methyl methacrylate) (PMMA) or a novel bone replacement copolymer, poly(propylene fumarate-co-caprolactone) [P(PF-co-CL)]. Axial rigidities were calculated from the CT images. Failure loads, determined from the cross section with the lowest axial rigidity, were compared with experimental values. Predicted loads correlated well with experimental outcomes (R-2 = 0.73, p < 0.0001). Predictions from negative control specimens highly correlated with measured values (R-2 = 0.90, p < 0.0001). Although a similar correlation was obtained using both algorithms, the smooth reconstruction (B30) tended to underestimate predicted failure loads by similar to 50% compared with the similar to 10% underestimate of the sharp reconstruction (B70). Percent increase in failure loads after virtual vertebroplasty showed a higher increase in samples with PMMA compared with those with copolymer. The SCA method developed in this study calculated failure loads from quantitative computed tomography scans in vertebrae with simulated metastatic lytic defects, with or without treatment, facilitating clinical applicability and providing more reliable guidelines for physicians to select appropriate treatment options. Furthermore, the analysis could accommodate augmentation planning procedures that aimed to determine the optimum material that would increase vertebral body failure load.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 细胞与组织工程 4 区 细胞生物学 4 区 工程:生物医学 4 区 材料科学:生物材料
JCR分区:
出版当年[2014]版:
最新[2023]版:
Q3 CELL & TISSUE ENGINEERING Q3 CELL BIOLOGY Q3 ENGINEERING, BIOMEDICAL Q4 MATERIALS SCIENCE, BIOMATERIALS

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版]

第一作者:
第一作者单位: [1]Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
通讯作者:
通讯机构: [1]Mayo Clin, Dept Orthoped Surg, Rochester, MN USA [4]Mayo Clin, Dept Physiol & Biomed Engn, 200 First St SW, Rochester, MN 55905 USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:589 今日访问量:0 总访问量:441 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)