Animal Experimental Study to Test Application of Intelligent Pressure Control Device in Monitoring and Control of Renal Pelvic Pressure During Flexible Ureteroscopy

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Nanchang Univ, Affiliated Ganzhou Hosp, Dept Urol, 17 Hongqi Ave, Ganzhou 341000, Jiangxi, Peoples R China [2]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Urol,Wuhan 430074,Hubei,Peoples R China
出处:
ISSN:

摘要:
OBJECTIVE To investigate the application of intelligent pressure control devices (medical irrigation and suctioning platform with pressure feedback function, and suctioning ureteral access sheath with pressure-measuring function) in flexible ureteroscopy for monitoring and control of renal pelvic pressure. MATERIALS AND METHODS Nine pigs with a total of 18 kidneys were randomly divided into 3 groups according to varied renal perfusion flow rates: group A, 50 mL/min; group B, 100 mL/min; and group C, 150 mL/min. A ureteral catheter connected to an invasive blood pressure monitor was retrogradely placed to the upper renal calyx to measure upper calyceal pressure; the suctioning sheath was connected to a 3-channel tubing and was connected to an invasive blood pressure monitor; and the platform and renal pelvic outlet pressure was measured. Perfusion flow, intraluminal pressure control, and warning values were preset on the platform. A flexible ureteroscope was inserted into the upper, mid, and lower renal calyces, and to the front end of the sheath, respectively, each location was irrigated for 5 minutes, and pressure was measured every second. RESULTS No statistical significance was found between monitor renal pelvic outlet pressure and platform renal pelvic outlet pressure for each group, or between platform renal pelvic outlet pressure and upper renal caliceal pressure for each group at different locations when varied irrigation flow rates were used, or among groups for platform renal pelvic outlet pressure at various irrigation flow rates. CONCLUSION The intelligent devices used in the flexible ureteroscopy can reliably and stably monitor and control the renal pelvic pressure within a safety range. (C) 2016 Elsevier Inc.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 3 区 医学
小类 | 3 区 泌尿学与肾脏学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 泌尿学与肾脏学
JCR分区:
出版当年[2014]版:
Q2 UROLOGY & NEPHROLOGY
最新[2023]版:
Q2 UROLOGY & NEPHROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
通讯作者:
通讯机构: [1]Nanchang Univ, Affiliated Ganzhou Hosp, Dept Urol, 17 Hongqi Ave, Ganzhou 341000, Jiangxi, Peoples R China [2]Huazhong Univ Sci & Technol,Tongji Hosp,Tongji Med Coll,Dept Urol,Wuhan 430074,Hubei,Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:428 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)