高级检索
当前位置: 首页 > 详情页

Schlemm's Canal and Trabecular Meshwork in Eyes with Primary Open Angle Glaucoma: A Comparative Study Using High-Frequency Ultrasound Biomicroscopy

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Ophthalmol,Wuhan 430074,Peoples R China
出处:
ISSN:

摘要:
We investigated in vivo changes in Schlemm's canal and the trabecular meshwork in eyes with primary open angle glaucoma (POAG). Relationships between Schlemm's canal diameter, trabecular meshwork thickness, and intraocular pressure (IOP) were examined. Forty POAG patients and 40 normal individuals underwent 80-MHz Ultrasound Biomicroscopy examinations. The Schlemm's canal and trabecular meshwork were imaged in superior, inferior, nasal and temporal regions. Normal individuals had an observable Schlemm's canal in 80.3% of sections, a meridional canal diameter of 233.0 +/- 34.5 mu m, a coronal diameter of 44.5 +/- 12.6 mu m and a trabecular meshwork thickness of 103.9 +/- 11.1 mu m, in POAG patients, Schlemm's canal was observable in 53.1% of sections, a meridional canal diameter of 195.6 +/- 31.3 mu m, a coronal diameter of 35.7 +/- 8.0 mu m, and a trabecular meshwork thickness of 88.3 +/- 13.2 mu m, which significantly differed from normal (both p < 0.001). Coronal canal diameter (r = -0.623, p < 0.001) and trabecular meshwork thickness (r = -0.663, p < 0.001) were negatively correlated with IOP, but meridional canal diameter was not (r = -0.160, p = 0.156). Schlemm's canal was observable in 50.5% and 56.6% of POAG patients with normal (< 21 mmHg) and elevated (> 21 mmHg) IOP, respectively (chi = 1.159, p = 0.282). Coronal canal diameter was significantly lower in the elevated IOP group (32.6 +/- 4.9 mu m) than in the normal IOP group (35.7 +/- 8.0 mu m, p < 0.001). This was also true of trabecular meshwork thickness (81.9 +/- 10.0 mu m vs. 97.1 +/- 12.0 mu m, p < 0.001). In conclusion, eyes with POAG had fewer sections with an observable Schlemm's canal. Canal diameter and trabecular meshwork thickness were also lower than normal in POAG patients. Schlemm's canal coronal diameter and trabecular meshwork thickness were negatively correlated with IOP.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 3 区 生物
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2014]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol,Tongji Med Coll,Tongji Hosp,Dept Ophthalmol,Wuhan 430074,Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:0 总访问量:412 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)