高级检索
当前位置: 首页 > 详情页

Evaluation of different mathematical models and different b-value ranges of diffusion weighted imaging in peripheral zone prostate cancer detection using b-value up to 4500 s/mm2

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Radiol, Tongji Med Coll, Wuhan, Hubei, Peoples R China [2]Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Ronald Reagan UCLA Med Ctr, Los Angeles, CA 90095 USA [3]Chinese Acad Sci, Key Lab Magnet Resonance Biol Syst, State Key Lab Magnet Resonance & Atom & Mol Phys, Natl Ctr Magnet Resonance,Wuhan Wuhan Inst Phys &, Wuhan, Hubei, Peoples R China [4]Univ Sci & Technol China, Ctr Biomed Engn, Hefei, Anhui, Peoples R China
出处:
ISSN:

摘要:
Objectives To evaluate the diagnostic performance of different mathematical models and different b value ranges of diffusion-weighted imaging (DWI) in peripheral zone prostate cancer (PZ PCa) detection. Methods Fifty-six patients with histologically proven PZ PCa who underwent DWI-magnetic resonance imaging (MRI) using 21 b-values (0-4500 s/mm(2)) were included. The mean signal intensities of the regions of interest (ROls) placed in benign PZs and cancerous tissues on DWI images were fitted using mono-exponential, bi-exponential, stretched-exponential, and kurtosis models. The b -values were divided into four ranges: 0-1000, 0-2000, 0-3200, and 0-4500 s/mm2, grouped as A, B, C, and D, respectively. ADC, <D>, D*, f, DDC, a, D-app, and K-app were estimated for each group. The adjusted coefficient of determination (R-2) was calculated to measure goodness-of-fit. Receiver operating characteristic curve analysis was performed to evaluate the diagnostic performance of the parameters. Results All parameters except D* showed significant differences between cancerous tissues and benign PZs in each group. The area under the curve values (AUCs) of ADC were comparable in groups C and D (p = 0.980) and were significantly higher than those in groups A and B (p<0.05 for all). The AUCs of ADC and Kapp in groups B and C were similar (p = 0.07 and p = 0.954), and were significantly higher than the other parameters (p<0.001 for all). The AUCs of ADC in group D was slightly higher than Kapp (p = 0.002), and both were significantly higher than the other parameters (p<0.001 for all). Conclusions ADC derived from conventional mono-exponential high b-value (3200 s/mm(2)) models is an optimal parameter for PZ PCa detection.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 3 区 生物
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2015]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Radiol, Tongji Med Coll, Wuhan, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:1 总访问量:413 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)