Intraoperative ultrasonography of robot-assisted laparoscopic hepatectomy: initial experiences from 110 consecutive cases

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Hepat Surg Ctr, Wuhan, Hubei, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Med Ultrasound Dept, Wuhan, Hubei, Peoples R China
出处:
ISSN:

关键词: Robot Ultrasonography Hepatectomy Laparoscopic

摘要:
To evaluate the safety and efficacy of IOUS in robotic liver surgery and propose a standard protocol of IOUS for safe robot-assisted hepatectomy. Between February 2015 and December 2016, liver resection was performed in 110 patients with robotic approach in Tongji Hospital. In these patients, IOUS was routinely performed. All data about demographic, surgical procedure, postoperative course were collected prospectively and analyzed. A four steps IOUS protocol in robotic liver surgery was proposed, including exploration, verification, guidance, and confirmation. A total of 11 additional lesions in 11 patients were detected and 7 patients accepted strategic surgical modification. No patient suffered from any single or multiple organ dysfunctions, and there were no mortalities observed. IOUS is indispensable to understand lesions and vessels in robotic liver surgery. A four-step standard protocol of IOUS is essential for safe robot-assisted hepatectomy.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 2 区 医学
小类 | 2 区 外科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 外科
JCR分区:
出版当年[2016]版:
Q1 SURGERY
最新[2023]版:
Q1 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Hepat Surg Ctr, Wuhan, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)