高级检索
当前位置: 首页 > 详情页

META-ANALYSIS: CONTRAST-ENHANCED ULTRASOUND VERSUS CONVENTIONAL ULTRASOUND FOR DIFFERENTIATION OF BENIGN AND MALIGNANT BREAST LESIONS

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA [2]Huazhong Univ Sci & Technol, Tongji Hosp, Dept Cardiovasc Surg, Tongji Med Coll, Wuhan, Hubei, Peoples R China [3]Fujian Med Univ, Union Hosp, Dept Ultrasound, Fuzhou, Fujian, Peoples R China [4]Chinese Peoples Liberat Army Gen Hosp, Dept Ultrasound, Southern Bldg, Beijing, Peoples R China [5]Shanghai Jiao Tong Univ, Clin Res Unit, Sch Med, Xin Hua Hosp, Shanghai, Peoples R China [6]Indiana Univ, Richard M Fairbanks Sch Publ Hlth, Dept Epidemiol, Indianapolis, IN 46204 USA [7]Huazhong Univ Sci & Technol, Union Hosp, Dept Ultrasound, Tongji Med Coll, 1277 JieFang Ave, Wuhan 430022, Hubei, Peoples R China [8]Huazhong Univ Sci & Technol, Union Hosp, Dept Ultrasound, Tongji Med Coll,Hubei Prov Key Lab Mol Imaging, 1277 JieFang Ave, Wuhan 430022, Hubei, Peoples R China
出处:
ISSN:

关键词: Breast Ultrasonography Contrast Diagnosis Meta-analysis

摘要:
This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS), conventional ultrasound (US) combined with CEUS (US + CEUS) and US for distinguishing breast lesions. From thorough literature research, studies that compared the diagnostic performance of CEUS versus US or US + CEUS versus US, using pathology results as the gold standard, were included. Atotal of 10 studies were included, of which 9 compared the diagnostic performance of CEUS and US, and 5 studies compared US + CEUS and US. In those comparing CEUS versus US, the pooled sensitivity was 0.93 (95% CI: 0.91-0.95) versus 0.87 (95% CI: 0.85-0.90) and pooled specificity was 0.86 (95% CI: 0.84-0.88) versus 0.72 (95% CI: 0.69-0.75). In studies comparing US + CEUS versus US, the pooled sensitivity was 0.94 (95% CI: 0.92-0.96) versus 0.87 (95% CI: 0.84-0.90) and pooled specificity was 0.86 (95% CI: 0.82-0.89) versus 0.80 (95% CI: 0.76-0.84). In terms of diagnosing breast malignancy, areas under the curve of the summary receiver operating characteristic (of both CEUS (p = 0.003) and US + CEUS (p = 0.000) were statistically higher than that of US. Both CEUS alone and US + CEUS had better diagnostic performance than US in differentiation of breast lesions, and US + CEUS also had low negative likelihood ratio. (E-mail: xiangfx@hotmail.com) (c) 2018World Federation for Ultrasound in Medicine & Biology. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 3 区 医学
小类 | 2 区 声学 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 声学 3 区 核医学
JCR分区:
出版当年[2016]版:
Q1 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者单位: [1]Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
通讯作者:
通讯机构: [7]Huazhong Univ Sci & Technol, Union Hosp, Dept Ultrasound, Tongji Med Coll, 1277 JieFang Ave, Wuhan 430022, Hubei, Peoples R China [8]Huazhong Univ Sci & Technol, Union Hosp, Dept Ultrasound, Tongji Med Coll,Hubei Prov Key Lab Mol Imaging, 1277 JieFang Ave, Wuhan 430022, Hubei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:0 总访问量:408 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)