高级检索
当前位置: 首页 > 详情页

Magnetic resonance neurography appearance and diagnostic evaluation of peripheral nerve sheath tumors

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Neurol, Wuhan 430022, Hubei, Peoples R China [2]Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Hubei, Peoples R China [3]Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430022, Hubei, Peoples R China
出处:
ISSN:

摘要:
Imaging appearances of peripheral nerve sheath tumors by MRI are difficult distinguish from soft-tissue tumors. The objective of this study was to evaluate the feasibility and imaging appearance of high-resolution 3-T magnetic resonance neurography (MRN) of the diagnosis of peripheral nerve sheath tumors (PNSTs) using sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) sequences. We retrospectively evaluated the MRI and 3D Short tau inversion recovery sampling perfection with application-optimized contrasts using varying flip-angle evolutions (3D-STIR SPACE) sequences of 30 patients with PNSTs diagnosed by surgery and pathology. The contrast-enhanced 3D-STIR SPACE images were retrospectively analyzed and evaluated for the visualization of PNSTs. The tumors were evaluated by their number, location, morphology, size, signal intensity and enhancement characteristics. The imaging findings and characteristic signs of conventional MRI scanning and contrast-enhanced 3D-STIR SPACE sequences were compared. In these cases, conventional MRI images display the location, number, shape, size and signal characteristics of the lesions. These tumors were mostly solitary and had a well-defined boundary. Compared to conventional MRI images, imaging appearances including neurogenic origin, length of the peripheral nerves and relation to the nerve of PNSTs on 3D-STIR SPACE images were more accuracy (P < 0.05). Compared to 3D-STIR SPACE images, contrast-enhanced images can more clearly display background suppression of the peripheral nerves. The "split fat" sign and "target" sign were seen in some patients. 3D STIR SPACE sequences demonstrate its significant capacity to diagnostic evaluate and location of PNSTs. This article comprehensively reviews radiologic findings and illustrates the MRN features of PNSTs. 3D-STIR SPACE sequences be used for preoperative evaluation of PNSTs.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2017]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Neurol, Wuhan 430022, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:0 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)