高级检索
当前位置: 首页 > 详情页

MYOCARDIAL DEFORMATION PATTERN DIFFERS BETWEEN ISCHEMIC AND NON-ISCHEMIC DILATED CARDIOMYOPATHY: THE DIAGNOSTIC VALUE OF LONGITUDINAL STRAINS

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Div Cardiol,Dept Internal Med, Wuhan 430030, Hubei, Peoples R China
出处:
ISSN:

关键词: Ischemic cardiomyopathy Non-ischemic cardiomyopathy Dilated cardiomyopathy 2-D speckle tracking echocardiography Longitudinal strain

摘要:
Both ischemic cardiomyopathy (ICM) and non-ischemic cardiomyopathy (NICM) are characterized by left ventricular (LV) dysfunction and dilation. Differentiation between ICM and NICM using non-invasive image modalities is a clinical challenge. This study compared the myocardial deformation patterns of ICM and NICM using 2-D speckle tracking echocardiography (2-D STE) and sought to find parameters valuable in the diagnosis and management of dilated cardiomyopathy. The study population comprised 84 consecutive patients with LV end-diastolic dimension >55 mm and ejection fraction (EF) <45 %. Of these patients, 41 were diagnosed with ICM and 43 with NICM by coronary angiography. 2-D STE was performed in all patients. The LV dimension did not differ between ICM and NICM. Compared with patients with ICM, patients with NICM had lower EF (29.0% vs. 33.0%, p = 0.024), lower global longitudinal strain (-5.4 +/- 2.6% vs. -7.0 +/- 2.5%, p = 0.006) and lower global radial strain (7.5 +/- 4.5% vs. 10.7 +/- 4.7%, p = 0.019). In contrast, global longitudinal strains did not differ significantly. However, NICM patients had higher apical and lower basal longitudinal strains compared with those with ICM. The ratio of basal to sum of mid- and apical longitudinal strains could predict NICM with a sensitivity of 63.4% and specificity of 88.4% by receiver operating characteristic curve analysis (cutoff value: 0.47, area under the curve: 0.792). Moreover, the concomitant presence of non-significant coronary artery stenosis (>50% and <70%) had no significant influence on global longitudinal strain in NICM. In conclusion, LV dilation and systolic dysfunction, relative apical sparing and a basal worsening pattern of LV longitudinal strain by 2-D STE were observed in patients with NICM but not ICM. The ratio of basal to sum of mid- and apical longitudinal strains could help differentiate NICM from ICM. (C) 2019 The Author(s). Published by Elsevier Inc. on behalf of World Federation for Ultrasound in Medicine & Biology.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 医学
小类 | 3 区 声学 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 声学 3 区 核医学
JCR分区:
出版当年[2018]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ACOUSTICS
最新[2023]版:
Q2 ACOUSTICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Div Cardiol,Dept Internal Med, Wuhan 430030, Hubei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:590 今日访问量:0 总访问量:442 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)