Cluster analysis of time evolution (CAT) for quantitative susceptibility mapping (QSM) and quantitative blood oxygen level-dependent magnitude (qBOLD)-based oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) mapping

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Cornell Univ, Dept Biomed Engn, Ithaca, NY USA [2]Weill Cornell Med Coll, Dept Radiol, New York, NY 10021 USA [3]Tongji Hosp, Dept Radiol, Wuhan, Hubei, Peoples R China [4]Heidelberg Univ, Comp Assisted Clin Med, Mannheim, Germany
出处:
ISSN:

关键词: cerebral metabolic rate of oxygen cluster analysis of time evolution K-means machine learning oxygen extraction fraction quantitative blood oxygenation level-dependent imaging quantitative susceptibility mapping

摘要:
Purpose To improve the accuracy of QSM plus quantitative blood oxygen level-dependent magnitude (QSM + qBOLD or QQ)-based mapping of the oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) using cluster analysis of time evolution (CAT). Methods 3D multi-echo gradient echo and arterial spin labeling images were acquired in 11 healthy subjects and 5 ischemic stroke patients. DWI was also carried out on patients. CAT was developed for analyzing signal evolution over TE. QQ-based OEF and CMRO2 were reconstructed with and without CAT, and results were compared using region of interest analysis and a paired t-test. Results Simulations demonstrated that CAT substantially reduced noise error in QQ-based OEF. In healthy subjects, QQ-based OEF appeared less noisy and more uniform with CAT than without CAT; average OEF with and without CAT in cortical gray matter was 32.7 +/- 4.0% and 37.9 +/- 4.5%, with corresponding CMRO2 of 148.4 +/- 23.8 and 171.4 +/- 22.4 mu mol/100 g/min, respectively. In patients, regions of low OEF were confined within the ischemic lesions defined on DWI when using CAT, which was not observed without CAT. Conclusion The cluster analysis of time evolution (CAT) significantly improves the robustness of QQ-based OEF against noise.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2018]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Cornell Univ, Dept Biomed Engn, Ithaca, NY USA
通讯作者:
通讯机构: [1]Cornell Univ, Dept Biomed Engn, Ithaca, NY USA [2]Weill Cornell Med Coll, Dept Radiol, New York, NY 10021 USA [*1]Weill Cornell Med Coll, Cornell MRI, Dept Radiol, 515 East 71st St,Suite 102, New York, NY 10021 USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:426 今日访问量:2 总访问量:410 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)