高级检索
当前位置: 首页 > 详情页

Cine magnetic resonance imaging for quantitative assessment of healthy volunteers and patients with organic small bowel disease

文献详情

资源类型:

收录情况: ◇ 统计源期刊

单位: [1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
出处:
ISSN:

关键词: smal bowel magnetic resonance (MR) cine quantitative assessment

摘要:
Objective The aim of the study was to use dynamic magnetic resonance imaging (MRI) to compare quantitative parameters of smal bowel motility between healthy volunteers and patients with smal bowel diseases in order to investigate the characteristics of normal and impaired bowel peristalsis. Methods A total of 44 healthy volunteers (20 men, 24 women; mean age: 36 years; range: 20–61 years) and 42 patients (28 men, 14 women; mean age: 44 years; range: 15–72 years) with organic smal bowel disease were recruited in our hospital (Tongji Hospital, Tongji Medical Col ege, Huazhong University of Sci-ence and Technology, Wuhan, China) in this prospective study approved by the hospital institutional review board. Imaging was performed using a 3.0-T scanner 45 minutes after standardized oral administration of 1500 mL non-absorbable fluid (2.5% mannitol). A serial coronal scan was performed at selected planes for two minutes without breath-hold. Time-caliber curves were plotted at two wel-distended smal bowel loops in both healthy and patient groups regardless of location. Luminal diameter (LD), contraction period (CP), frequency of contraction (FC), and amplitude-diameter ratio (ADR) were measured based on the graph. Results The characteristics of abnormal peristaltic parameters were assessed in dif erent patients and compared to normal curves from healthy volunteers. A total of 37 segments with abnormal motility were confirmed by two readers in consensus, based on curve patterns and the presence of a stationary phase. Compared to normal peristalsis in healthy volunteers, five dif erent patterns of impaired peristalsis were identified: I, consecutive; II, slow; III, giant type; IV, uncoordinated; and V, akinetic. Dilated LDs were de-tected in al instances of abnormal peristalsis (P < 0.05). Increased frequency was found in type I [(8.73 ± 1.15) /min], while decreased frequency was detected in type III peristalsis [(0.67 ± 0.29) /min]. There were no significant dif erences in frequency between type II [(3.19 ± 0.43) /min] and normal peristalsis [(3.45 ± 0.57) /min]. Apart from type I [(8.70 ± 0.75) /min], increased FCs were found in al other abnormal patterns. In type II peristalsis, the average ADR value was 0.82 ± 0.08, comparable to the ADR value in the healthy group (0.83 ± 0.13). Conclusion MR cine is an ef ective method for dif erentiating normal and abnormal smal bowel peristal-sis. Plotting time-caliber curves and measuring quantitative MR cine parameters such as LD, CP, FC, and ADR of ers more precise information about smal bowel motility.

基金:
语种:
第一作者:
第一作者单位: [1]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:432 今日访问量:1 总访问量:413 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)